Execute the debug rxtx softcar show 1 command in en_diag view to check for
software-related packet loss.
<Sysname> system-view
[Sysname] probe
[Sysname-probe] debug rxtx softcar show slot 1
ID Type RcvPps Rcv_All DisPkt_All Pps Dyn Swi Hash Am APps
0 ROOT 0 0 0 200 S On SMAC 0 0
1 ISIS 0 0 0 200 D On SMAC 8 512
2 ESIS 0 0 0 100 S On SMAC 8 512
3 CLNP 0 0 0 100 S On SMAC 8 512
4 VRRP 0 0 0 1024 S On SMAC 8 768
5 UNKNOWN_IPV4MC 0 0 0 100 S On SMAC 8 1024
6 UNKNOWN_IPV6MC 0 0 0 100 S On SMAC 8 1024
7 IPV4_MC_RIP 0 0 0 150 D On SMAC 8 512
8 IPV4_BC_RIP 0 0 0 150 D On SMAC 8 512
9 MCAST_NTP 0 0 0 100 S On SMAC 8 512
10 BCAST_NTP 0 0 0 100 S On SMAC 8 512
11 IPV4_MC_OSPF_5 0 0 0 100 S On SMAC 8 512
12 IPV4_MC_OSPF_6 0 0 0 100 S On SMAC 8 512
13 IPV4_UC_OSPF 0 0 0 200 S On SMAC 8 512
14 IPV4_MC_PIM 0 0 0 100 S On SMAC 8 512
15 IPV4_UC_PIM 0 0 0 100 S On SMAC 8 512
16 IPV4_IGMP 0 0 0 100 S On SMAC 8 512
17 LDP 0 0 0 100 S On SMAC 8 512
18 IPV6_MC_PIM 0 0 0 100 S On SMAC 8 512
19 IPV6_UC_PIM 0 0 0 100 S On SMAC 8 512
20 IPV6_MLD 0 0 0 100 S On SMAC 8 512
21 IPV6_RIPNG 0 0 0 100 D On SMAC 8 512
...
3. If the issue persists, contact H3C Support.
When you contact H3C Support, provide diagnostic information if software-related packet loss
occurred.
VXLAN configuration failure
Symptom
On a switch that acts as a leaf node, the system displays "The operation is not supported." message
when one of the following operations is performed:
Configure the L3 VXLAN ID in VSI interface view.
Execute the vxlan command in VSI view.