5-37
Field
Description
Swap Swap memory.
Displaying the operational status of power
modules
Use the display power command to display the operational status of power modules.
<Sysname> display power
Power 0 Status: Normal
Power 1 Status: Absent
Table5-4 Output description
Field
Description
Power Number of the power module.
Status
Power module state:
NormalThe power module is operating correctly.
AbsentThe power module is not in position.
AbnormalThe power module has failed.
Displaying the temperature information of the
firewall
IMPORTANT:
Only F1020, F1030, F1050, F1060, F1070, F1080, and F1090 firewalls support the
display
environment command.
Use the display environment command to display the temperature information of the firewall.
<Sysname> display environment
System Temperature information (degree centigrade):
--------------------------------------------------------------------------------
---------
Sensor Temperature LowerLimit Warning-UpperLimit Alarm-UpperLimit Shutdown-U
pperLimit
inflow 1 26 -5 48 56 NA
Table5-5 Output description
Field
Description
Sensor
Temperature sensor:
inflowAir inlet vent temperature sensor.
outflowAir outlet vent temperature sensor.
hotspotHotspot temperature sensor.
Temperature Current temperature.
LowerLimit Low temperature alarm threshold.

Table of Contents

Other manuals for H3C SecPath F10 0 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C SecPath F10 0 Series and is the answer not in the manual?

H3C SecPath F10 0 Series Specifications

General IconGeneral
BrandH3C
ModelSecPath F10 0 Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals