EasyManuals Logo

H3C WA2600 Enhanced Series Installation Manual

H3C WA2600 Enhanced Series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
2-5
z If the voltage is unstable, a voltage regulator or stabilizer is
required.
z An uninterrupted power supply (UPS) is required for
uninterrupted communication.
Grounding and Lightning Protection
Table 2-5 Grounding and lightning protection requirements
Item Requirements
Grounding
resistance
z The grounding resistance is typically required to
be less than 5 ohms, and less than 10 ohms in an
area that has less than 20 thunderstorm days a
year. If an angle iron is to be buried into the earth
as the earthing conductor, the grounding
resistance is required to be less than 10 ohms. If
the installation site has a high earth resistance
rate, it is recommended to spray some salt water
or resistance-reducing agent on the earth around
the buried earthing conductor to reduce the
resistance rate of the earth.
z The top of the earthing conductor should be at
least 0.7 m (2.30 ft) away from the ground
surface. In cold areas, the earthing conductor
should be buried below the frozen soil layer.

Table of Contents

Other manuals for H3C WA2600 Enhanced Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C WA2600 Enhanced Series and is the answer not in the manual?

H3C WA2600 Enhanced Series Specifications

General IconGeneral
BrandH3C
ModelWA2600 Enhanced Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals