283
PARAMETERS
June 1999
96-8000
Parameter 123 Z PHASE OFFSET
See Parameter 121 for description.
Parameter 124 A PHASE OFFSET
See Parameter 121 for description.
Parameter 125 X GRID OFFSET
This parameter shifts the effective position of the encoder Z pulse. It can correct for a
positioning error of the motor or home switch.
Parameter 126 Y GRID OFFSET
See Parameter 125 for description.
Parameter 127 Z GRID OFFSET
See Parameter 125 for description.
Parameter 128 A GRID OFFSET
See Parameter 125 for description.
Parameter 129 GEAR CH SETTLE TIME
Gear change settle time. This is the number of one millisecond samples that the gear status
must be stable before considered in gear.
Parameter 130 GEAR STROKE DELAY
This parameter controls the delay time to the gear change solenoids when performing a gear
change.
Parameter 131 MAX SPINDLE RPM
This is the maximum RPM available to the spindle. When this speed is programmed, the D-to-
A output will be +10V and the spindle drive must be calibrated to provide this.
Parameter 132 Y SCREW COMP. COEF.
This is the coefficient of heating of the lead screw and is used to decrease or shorten the
screw length.
Parameter 133 Z SCREW COMP. COEF.
This is the coefficient of heating of the lead screw and is used to decrease or shorten the
screw length.
Parameter 134 X EXACT STOP DIST.
Parameter 135 Y EXACT STOP DIST.
Parameter 136 Z EXACT STOP DIST.