52
English
Dialock Door Terminals DTSH, DTSH FH - Status: 07.2008 - 732.29.134
Installation Instructions
Only required with emergency opening log!
Drilling jig parts A-CFig. 22
Drill through to the middle of the door
leaf from both sides using the 8 mm
drill bit to connect the emergency
opening log. (Centring hole for 32 mm
router cutter)
This procedure can
destroy the connecting
cable for emergency
opening log. The con-
necting cable must not
be routed in the lock
pocket at location A,
fig. 22!
Fig. 23
Remove mortise lock
from lock pocket!
Depth cutting as far as lock pocket.
Page 49, fig. 15, section A-A.
A