Explains the structure and meaning of the product model number.
Provides critical safety warnings and precautions for servicing and operating the unit.
Illustrates the refrigerant circuit and component layout for cooling operation.
Illustrates the refrigerant circuit and component layout for heating operation.
Lists and describes all connectors on the control PCB.
Lists and describes all connectors on the module PCB.
Details the primary operational functions and control specifications.
Explains compressor frequency control and limitations.
Describes how the outdoor fan speed is managed.
Covers various protection mechanisms including TTC, TC, over-current, anti-freezing, etc.
Details the operation of the four-way reversing valve.
Provides thermistor resistance values across temperature ranges.
Key warnings and prerequisites for accurate fault diagnosis.
Lists common operational issues and recommended troubleshooting steps.
Explains error codes displayed by the unit and their causes.
Troubleshooting guide for thermistor failures.
Procedures for diagnosing and resolving EEPROM errors.
Steps to diagnose issues with the indoor fan motor.
Steps to diagnose problems with the outdoor DC fan motor.
Addresses faults related to IPM protection.
Troubleshooting guide for compressor over-current conditions.
Diagnosing communication failures between IPM and outdoor PCB.
Troubleshooting power supply voltage irregularities.
Diagnosing and resolving overheat protection for discharge temperature.
Troubleshooting communication errors between indoor and outdoor units.
Diagnosing compressor rotor synchronism loss.
Troubleshooting issues related to high work-intense protection.
Graphical representation of cooling capacity at various temperatures.
Graphical representation of power consumption at various temperatures.
Graphical representation of discharge pressure at various temperatures.
Graphical representation of suction pressure at various temperatures.
Graphical representation of heating capacity at various temperatures.
Graphical representation of heating power consumption at various temperatures.
Graphical representation of heating discharge pressure at various temperatures.
Graphical representation of heating suction pressure at various temperatures.
Detailed circuit schematics for the outdoor control board.
Detailed circuit schematic for the module board.
Step-by-step guide to safely detach the outdoor unit's casing.
Step-by-step guide to remove the electrical component housing.
Step-by-step guide to detach the fan and its motor.
Step-by-step guide to remove the fan motor mounting bracket and partition.
Step-by-step guide to detach the compressor and heat exchanger.