Specification
Domestic air conditioner
TECHNICAL SPECIFICATIONS-OTHERS
Refrigerant
circuit
Refrigerant type R410a
Refrigerant charge KG 0.78
Maximum allowable distance
between indoor an outdoor
m 15
Maximum allowable level difference m 10
Refrigerant control Capillary
Piping connections
(external diameter)
liquid mm Φ6.35
gas mm Φ9.52
drain mm Φ16
Heat insulation type Both liquid and Gas pipes
Max. piping Length m 15
Max. vertical Difference m 10
Chargeless m 7
Amount of Additional Charge of Refrigerant g/m 20
Intemational Protection degree IP 24
Note: the data are based on the conditions shown in the table below
cooling heating Piping length
Indoor: 27 DB/19 WBćć
Outdoor: 35 DB/24 WBćć
Indoor:20 DBć
Outdoor: 7 DB/6 WBćć
5m
3ˊSensors list
type Description Qty
Ambient sensor Its used for detecti 1 edis roodtuo fo erutarepmet gn
Defrosting sensor Its used for controlling outdoor defrosting at heating mode 1
1 taeh-revo fo esac ni rosserpmoc rof desu stI rosnes gnigrahcseD
Conversation formulae
Kcal/h= KW×860
Btu/h= KW×3414
cfm=m³/min×35.3