Cooling Capacity | 12000 BTU/h |
---|---|
Energy Efficiency Ratio (EER) | 3.21 |
Refrigerant | R410A |
Weight (Indoor Unit) | 10 kg |
Weight (Outdoor Unit) | 28 kg |
Noise Level (Indoor) | 38 dB(A) |
Noise Level (Outdoor) | 52 dB(A) |
Power Supply | 220-240V, 50Hz |
Operating Temperature (Heating) | -7-24°C |
Heating Capacity | 13000 BTU/h |
Operating Temperature (Cooling) | 18°C to 43°C |
Outdoor Unit Dimensions (W x H x D) | 780 x 540 x 250 mm |
Essential safety warnings and symbols for proper installation and operation.
Explains the ductless system's features, specifications, and fundamental operating principles.
Overview and visual identification of the outdoor unit's main parts and functions.
Detailed descriptions of the terminal block, compressor, fan motor, and temperature sensors.
Explains the function of the 4-way valve, accumulator, and electronic expansion valve.
Overview and visual identification of the indoor unit's main parts and functions.
Details the indoor control board's connectors and the function of the unit's display panel.
Explains the ambient/piping sensors, louver motor, fan motor, and emergency button.
Explains the functions of various buttons like Power, Turbo/Quiet, Cool, Heat, Auto, and Fan.
Details airflow direction adjustment, Timer ON/OFF functions, and SLEEP mode operation.
Covers system power connection and the detailed operation sequence for cooling mode.
Explains system behavior during heating, automatic switching, and dry (dehumidification) modes.
Describes system protection mechanisms and the defrost cycle operation.
Covers required tools, location selection, and mounting procedures for indoor and outdoor units.
Details electrical wiring for both units and interconnecting the indoor and outdoor units via piping.
Outlines the critical steps for leak testing, system evacuation, and refrigerant charging.
Covers test run checks, user operation explanation, and system specifications.
Lists error codes, their indications on indoor/outdoor displays, and fault descriptions.
Provides diagnostic flowcharts for common issues like fan motor faults, IPM protection, and communication errors.
Covers overheat protection, communication faults, and detailed procedures for checking system components.
Contains electrical wiring diagrams and circuit schematics for the outdoor and indoor control boards.
Provides tables for ambient, defrost, pipe, and discharge sensor resistance values across temperature ranges.