EasyManua.ls Logo

Haier 1U12TE1VHA - Ambient, Defrosting, Pipe Sensor Tables

Haier 1U12TE1VHA
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REFERENCE INFORMATION
PAGE 6
ENGLISH
Temp°F Temp. °C M) ) ) Tolerance (°C)
75.0 3.153 3.026 2.899 4.19 4.19
76.0 3.046 2.922 2.798 4.23 4.23
77.0 2.944 2.823 2.702 4.28 4.28
78.0 2.845 2.727 2.609 4.32 4.32
79.0 2.751 2.636 2.521 4.36 4.36
80.0 2.659 2.547 2.435 4.41 4.41
81.0 2.573 2.463 2.353 4.45 4.45
82.0 2.488 2.381 2.274 4.49 4.49
83.0 2.407 2.303 2.199 4.54 4.54
84.0 2.329 2.227 2.125 4.58 4.58
85.0 2.253 2.154 2.054 4.63 4.63
86.0 2.182 2.085 1.988 4.67 4.67
87.0 2.112 2.017 1.922 4.71 4.71
88.0 2.046 1.953 1.860 4.76 4.76
89.0 1.981 1.890 1.799 4.80 4.80
90.0 1.919 1.830 1.741 4.84 4.84
91.0 1.859 1.772 1.685 4.89 4.89
92.0 1.801 1.716 1.631 4.93 4.93
93.0 1.745 1.662 1.579 4.98 4.98
94.0 1.691 1.610 1.529 5.02 5.02
95.0 1.639 1.560 1.481 5.06 5.06
96.0 1.589 1.512 1.435 5.11 5.11
97.0 1.540 1.465 1.390 5.15 5.15
98.0 1.494 1.420 1.346 5.19 5.19
99.0 1.449 1.377 1.305 5.24 5.24
100.0 1.406 1.335 1.264 5.28 5.28
101.0 1.363 1.294 1.225 5.33 5.33
102.0 1.322 1.255 1.188 5.37 5.37
103.0 1.283 1.217 1.151 5.41 5.41
104.0 1.244 1.180 1.116 5.46 5.46
105.0 1.208 1.145 1.082 5.50 5.50
ENGLISH
Ambient Sensor Tables