Functions and control 
16  Domestic air conditioner
3  Wh_c<-2  Max_hz3  99HZ 
4  Wh_c<5  Max_hz4  93HZ 
5  Wh_c<10  Max_hz5  82HZ 
6  Wh_c<17  Max_hz6  66HZ 
7  Wh_c<20  Max_hz7  59HZ 
8
Wh_c>
20
Max_hz8  51HZ 
Remarks:  The  above  are  the  maximum  frequency  limitations  of  the  complete  appliance  which  are 
affected by the environment, and they have nothing to do with the ability of the indoor unit. 
Refrigeration/dehumidification mode: 
Serial No.  Temperature scope 
Frequency limitation
09K
1  Wh_c<16  Max_hz1  44HZ 
2  Wh_c<22  Max_hz2  49HZ 
3  Wh_c<29  Max_hz3  56HZ 
4  Wh_c<32  Max_hz4  63HZ 
5  Wh_c<40  Max_hz5  75HZ 
6  Wh_c<48  Max_hz6  55HZ 
7  Wh_c>=48  Max_hz7  39HZ 
Remarks: the above are not only the maximum frequency limitations of the complete appliance 
which are affected by the environment, but also the maximum ability limitation of the system. When the 
starting  ability  is  not  the  maximum,  its  maximum  frequency  limitation  is  calculated  by  the  following 
equations: 
The frequency limitation which is affected by the temperature and under the condition of actual 
ability
the actual running system ability*the maximum frequency which is limited by the temperature 
and under the condition of maximum ability/the maximum designing ability of the system 
Refrigeration/dehumidification mode: 
Heating mode: 
       
The calculation of the actual output frequency: 
F= F-ED-*(rated frequency)
K
F-ED-*(rated frequency)= The frequency which is limited by the outdoor environment temperature
Notes:
When refrigerating, it is needed to satisfy 
The indoor setting 
airflow speed 
Low  Medium  Quiet 
The percentage of the 
rated frequency K 
(09K) 
70%  85% 42% 
The indoor setting 
airflow speed 
Low  Medium  Quiet 
The percentage of the 
rated frequency K 
(09K) 
80%  90% 50%