Indoor display
     E7 
outdoor display
    LED1 flash  15 times
Method of   
  Communication is detected by checking the indoor PCB and the outdoor PCB
Malfunction       
Detection 
Malfunction      Ŷ
The outdoor PCB broken leads to communication fault
Decision Ŷ
  The indoor PCB broken leads to communication fault
Conditions   
Supposed         Ŷ Communication wiring disconnected 
Causes  Ŷ
The indoor PCB is broken     
The Module PCB is broken 
Troubleshooting    
* Caution 
Be sure to turn off power switch before connect or disconnect connector,      or 
else parts damage may be occurred.   
NO
˄A˅
Yes
NO
Yes
No 
YES 
Restart the a/c and it 
becomes normally. 
If starting up normally, but 
malfunction occurs again after a 
while  
Check whether the linking cable 
between the indoor and outdoor is well 
connected or whether its core wires are 
well insulated. 
The outdoor mainboard needs 
dehumidification.
The outdoor mainboard needs 
dedust.
1. Reconnect the linking cable; 
2. Replace the linking cable with new 