173
00: Unavailable Health function;
01: Available Health
function.
(3) Mode Setting (Only valid for part of models):
After entering the advanced setting, press the Fan key to
change the function from A to b, The function code 01 display
in the clock display area
The mode setting function
can be inquired or adjusted.
00: Intelligent +Heating +Dry +Cooling +Fan
01: Auxiliary heating (reserved) +Heating +Dry +Cooling +Fan
02: Dry +Cooling +Fan
03: Heating +Dry +Cooling +Fan
04: Heating +Cooling +Fan
(4) The way of humility collection (Only valid for part of
models):
After entering the advanced setting, press the Fan key to
change the function from A to b, The function code 01 display
in the clock display area
Press Up/Down key to
change the function code to 12, At this time press SET key to
The function code 12 display in the clock display area
statically, and the detailed information in the timing display
area
Press the Up/Down key to change the content
and the SET key to
00: Collect data from humidity sensor of wired controller
01: Collect data from humidity sensor of indoor PCB
(5) Energy Saving/ 26°C lock function (Only valid for part of
models):
After entering the advanced setting, press the Fan key to
change the function from A to b, The function code 01 display
in the clock display area
Press Up/Down key to
change the function code to 21, At this time press SET key to
The function code 21 display in the clock display area
statically, and the detailed information in the timing display
area
Press the Up/Down key to change the content
and the SET key to
00: Unavailable Energy Saving Function
01: Available Energy Saving Function
(6) Indoor RH data Collection (Only valid for part of models):
After entering the advanced setting, press the Fan key to
change the function from A to C, The function code 01 display
in the clock display area
At this time press SET key to
The function code 01 display in the clock display area
statically, and the detailed information in the timing display
area
Press the Up/Down key to change the content
and the SET key to
30: The value of Relative humility is 30%;
31: The value of Relative humility is 31%;
…………………………………………..;
90: The value of Relative humility is 90%;
(7) Manual Defrosting (Only valid for part of models):
After entering the advanced setting, press the Fan key to
change the function from A to E, The function code 01 display
in the clock display area
Press Up/Down key to
change the function code to 21, At this time press SET key to
The function code 21 display in the clock display area
statically, and the
information in the timing display
area
press the Up/Down key to changed the content
and the SET key to
00: Unavailable Manual Defrost
01: Available Manual Defrost
Wiring Connections of Wire Controller
A
A A A A A
A
B B B B B
B
C C C C C
C
Indoor 1 Indoor 2 Indoor N Indoor 15 61 roodnI
(master unit)
Wire controller Wire controller Wire controller Wire controller Wire controller
Wire controller
Control wiring of wire
controller, polar.
B
A
A
B
B
C
C
Indoor 1
Polar wire
Wire controller
Wire controller
A
A A
B
B B
C
C C
Polar wire
Polar wire
Indoor 1
Wire controller Wire controller
Wire controller
C
D
A A A A A
A
B B B B B
B
C C C C C
C
Indoor 1 Indoor 2 Indoor N Indoor 15 61 roodnI
(master unit)
Wire controller Wire controller Wire controller Wire controller Wire controller
Wire controller
Control wiring of wire
controller, polar.
Notice:
For wired controller connection, please do follow the
corresponding indoor unit installation manual's instruction.
There are four methods to connect wired controller with the
indoor units
A. One wired controller can control max. up to 16 sets of
indoor units, and 3 pieces of polar wire must connect
the wire controller and the master unit (the indoor unit
connected with wire controller directly), the others connect
with the master unit through 2 pieces of polar wire.
B. One wire controller controls one indoor unit, and the indoor
unit connects with the wire controller through 3 pieces of
polar wire.
C. Two wired controllers control one indoor unit. The wired
controller connected with indoor unit is called master
one, the other is called slave one. Master wired controller
and indoor unit; master and slave wire controllers are all
connected through 3 pieces of polar wire.