10.2 Trouble Shooting - Detailed for engineer 
Malfunction flow chart: analyze and diagnose 
If the air-condition fails to cooling or heating function and other functions, please check 
the system as follows: 
 
1.Cooling  
Y
change the designed 
TEMP.
replacing compressor
superaddition condensate
clear the filter
enact fan speed of 
high or middle speed
airiness circle 
improperly
heat insulation of condensate 
pipeline between indoor unit 
and outdoor unit  is normal
N
N
compressor fault
quantity of condensate 
charge is not enough
fan speed at 
low-speed
air entrance filter 
obstruct
Y
Y
Y
Y
condensate 
flowage failure
fails in cooling
begining
N
N
fault in 4-way vavle
 the cooling load 
beyond the allowable 
arange
 
the enactment TEMP. 
right or not
Y
Y
Y
insulate the two 
pipeline respective 
redesign the TEMP.
change the 
4-way vavle
use arange is right 
or not
Y
 
Figure 7-1 
-50-