192
A
¡æ
B
C
D
E
Shape the wires so that
there is no lifting of the 
service hatch or other
structural parts
Use the specified
wires and connect
them securely.
Secure the branch wiring firmly using the 4
included screws, as shown in the figure.
Secure firmly, making sure no outside 
pressure is exerted on the terminals.
4. Wiring Method of Indoor Unit
Loosen wire cover and connect the power cord and communication wire of indoor unit to the terminal 
correspondingly.
Note:
When connecting power cord to power supply terminal, please pay attention to the following items:
• Do not connect the power cord with different dimensions to the same connection wire end. Improper contact will 
cause heat generation.
• Do not connect the power line with different dimensions to the same grounding wire end. Improper contact will 
affect protection.
• Do not connect the power line to the connecting end of communication wire. Incorrect connection will cause 
damage to the connected unit.
• The wiring should ensure that the ground line is the last one to be broken off by force.
5. Example wiring diagram.