Dear Haier users,
Thank you for selecting and using Haier products.
Haier provides products of excellent quality and good performance. For your convenience of use, please
read and follow this manual carefully. Haiers international star-class service is always available to you.
If you have any problem during operation, please contact with us byt telephone number or address on
the warranty. We are always at your service.
Haier Sincere Forever!
The Haier modular air-cooled unit you purchased may not be fully consistent with this Manual due to
product improvement. We apologize for such inconvenience (if any) to you.
Notes to users:
Please pay attention to the following notes for the proper use and maintenance, more efficient operation
and
longer service life of unit:
1. This Manual includes information necessary for the proper installation, commissioning, startup and
maintenance, so please read it carefully before the startup or maintenance.
2. Installation must be performed by trained professionals.
3. For the first startup, please follow the steps herein to ensure personal and unit safety. The first
startup shall be carried out under the guidance of our professional commissioning personnel or
assigned personnel.
National standard applied:
GB/T 18430.1-2007
One World, One Home
Installation and Operation Manual of
Commercial Air Conditioner
This Manual applies to modular air-cooled (heat pump)
chiller units
Modle: CA0035EAND
CA0070EAND
CA0100EAND
CA0130EAND
Please read this Manual carefully before operation.
Safekeep this Manual for future reference.

Other manuals for Haier CA0035EAND

Questions and Answers

  • D
    Daniel NguyenAug 22, 2025
    Why is the suction pressure high in my Haier Air Conditioner?
    • E
      Edwin HerreraAug 22, 2025
      High suction pressure in your Haier Air Conditioner can be caused by: * Too high charge of refrigerant, so you should adjust the charge of refrigerant. * High water inlet temperature at the water side, so you should check the water temperature. * High ambient temperature of the air-side heat exchanger, so you should inspect the ambient temperature.
  • S
    Shelia OlsonSep 6, 2025
    What to do if my Haier CA0035EAND has low suction pressure?
    • A
      Alicia HessSep 6, 2025
      If your Haier Chiller has low suction pressure, it could be due to insufficient refrigerant (adjust the charge), a faulty low-pressure switch (replace it), insufficient water flow (check the water flow), low water inlet temperature at the water side (check the water temperature), scaling or foreign matter inside the water-side heat exchanger (clean up the incrustation scale), insufficient air capacity (check the fan), a short circuit in the air circuit (check the cause and troubleshoot), or incomplete defrosting (replace the poor 4-way valve or defrosting sensor).
  • J
    joseph14Sep 3, 2025
    What causes an open or short circuit in the temperature sensor of a Haier Air Conditioner?
    • T
      tammystewartSep 3, 2025
      An open or short circuit in the temperature sensor of your Haier Air Conditioner may be due to: * Damaged sensor: Replace the sensor. * Poor connection of sensor: Reconnect the sensor.
  • B
    bwrightSep 2, 2025
    What to do if there is a fault in communication of the wired controller of my Haier Air Conditioner?
    • C
      Chelsea HarrisSep 2, 2025
      A fault in the communication of the wired controller for your Haier Air Conditioner can be caused by: * Incorrect unit numbering: Check the unit numbering and correct it. * Incorrect connection of communication wires: Check the order of connection of communication wires. * Damaged PCB: Replace the PCB. * Poor wired controller: Replace the wired controller.
  • M
    megan13Sep 1, 2025
    Why is the exhaust temperature sensor overheating on my Haier Air Conditioner?
    • N
      nwoodardSep 1, 2025
      Overtemperature of the exhaust temperature sensor in your Haier Air Conditioner may be caused by: * Poor ventilation around the unit: Clean up obstacles or add air ducts. * Too low ambient temperature: Shut down the unit. * Dirty or clogged filter at the fluorine side: Replace the filter. * Incomplete frosting (for heating) or no frosting: Change the frosting parameters.
  • J
    Joseph NavarroAug 30, 2025
    What causes a fault in the flow switch of my Haier Air Conditioner?
    • K
      Kristin WoodsAug 30, 2025
      A fault in the flow switch of your Haier Air Conditioner can occur due to: * Air in the water system: Discharge air via the exhaust valve. * Water-side heat exchanger scaling or foreign matter inside: Clean up the incrustation scale. * Poor switch: Replace the target flow switch. * Unevenly distributed flow in water pipelines: Adjust the flow in water pipelines via the shut-off valve. * Out-of-service water pump: Machine installation must be ganged. * Insufficient types of water pumps: Check it and try to fix it.
  • Q
    qmunozAug 29, 2025
    What causes an over-current fault in the compressor of a Haier Air Conditioner?
    • M
      Monica BuckleyAug 29, 2025
      An over-current fault in the compressor of your Haier Air Conditioner may be due to: * High exhaust pressure and high suction pressure: Refer to “High Exhaust Pressure” and “High Suction Pressure”. * High or low voltage, single phase or phase imbalance: Check the power supply. * Short circuit in motor or terminal: Check the terminal connections.
  • O
    okempAug 27, 2025
    What to do if the exhaust pressure is too low on my Haier Air Conditioner?
    • L
      Lisa PierceAug 28, 2025
      Too low exhaust pressure in your Haier Air Conditioner can be caused by: * Lack of refrigerant: Adjust the charge of refrigerant. * Low suction pressure: Refer to “Low Suction Pressure”. * Low ambient temperature of the air-side heat exchanger: Check the ambient temperature. * Too low water temperature at the water side: Check the water temperature.
  • A
    Amanda FosterAug 27, 2025
    How to fix abnormal noise in Haier Air Conditioner?
    • J
      John MortonAug 27, 2025
      Abnormal noise in your Haier Air Conditioner can be caused by: * Loose metal plate bolts: Retighten the bolts. * Liquid impact due to entry of liquid refrigerant into the compressor: Adjust the charge of refrigerant or the poor throttling device. * Poor compressor: Replace the compressor.
  • M
    Michelle OconnorAug 25, 2025
    What causes low suction pressure in my Haier Air Conditioner?
    • K
      katherine02Aug 26, 2025
      Low suction pressure in your Haier Air Conditioner may occur due to: * Insufficient refrigerant: Adjust the charge of refrigerant. * Undesirable low-pressure switch: Replace the low-pressure switch. * Insufficient water flow: Check the water flow. * Low water inlet temperature at the water side: Check the water temperature. * Water-side heat exchanger scaling or foreign matter inside: Clean up the incrustation scale. * Insufficient air capacity: Check the fan. * Short circuit in the air circuit: Check the cause of the short circuit and troubleshoot. * Incomplete defrosting: Replace the poor 4-way valve or defrosting sensor.

Summary

Product Introduction

Overview

Details the unit's features, applications, reliability, safety, and adaptability.

High efficiency and energy saving

Explains how the unit uses advanced technology for efficient operation and energy savings.

Easy control

Describes the unit's electronic controller for centralized and independent operation.

Convenient installation

Highlights the unit's design for simplified installation and space efficiency.

Safe operation

Covers the unit's safety features like pressure protection and anti-freezing.

Convenient maintenance

Mentions easy access to parts for maintenance and troubleshooting.

Safety Precautions

Symbol description

Explains the meaning of warning and caution symbols used in the manual.

WARNING

Provides critical safety information regarding installation and maintenance by professionals.

CAUTION

Advises on proper installation locations and operational precautions to avoid damage.

Controller Operation Instruction

Description of controller panel

Details the physical layout and components of the wired controller interface.

Key description of wired controller

Explains the function of each button on the wired controller for system operation.

Description of Basic Operation of Wired Controller

Guides on starting up, operating modes, and temperature adjustments using the controller.

Description of Controller Display

Explains how to interpret information displayed on the controller's main interface.

Interface of Week Timing mode

Instructions for setting up daily startup and shutdown schedules for the week.

Interface of Cycle Timing mode

Instructions for setting up cyclical startup and shutdown schedules.

Interface of Day Timing mode

Instructions for setting up daily specific startup and shutdown times.

Timing Disabled mode

Explains how to disable the unit's timing functions.

Installation

Drawing of Overall Dimension

Provides dimensional drawings and measurements for the CA0035EAND unit.

Reference Position of Base

Guidelines for designing and preparing the unit's installation base.

Unit Base Diagram

Illustrates the base mounting points and dimensions for unit installation.

Unit Base Diagram

Shows base mounting details for CA0070EAND, CA0100EAND/CA0130EAND units.

Pre-installation Preparation

Covers essential steps like cargo inspection, handling, and disassembly before installation.

Selection Installation Position

Provides criteria for selecting an optimal and safe installation location.

Diagram of installation space for single chiller unit

Shows the required clearance and space for installing a single chiller unit.

Diagram of installation space for multiple chiller units

Illustrates the necessary spacing for installing multiple chiller units together.

Diagram of arrangement of multiple chiller units

Provides visual guidance on the physical layout of multiple chiller units.

Water Pipe Connection

Details the procedures and requirements for connecting the unit's water piping system.

Water quality control

Specifies the acceptable water quality parameters for system operation.

SCHEMATIC DIAGRAM of WATER SYSTEM

Presents a visual representation of the water system components and connections.

Basic requirements

Outlines fundamental requirements for setting up the chilled water pipeline system.

Electrical Connection

Provides instructions and safety guidelines for connecting the unit's electrical wiring.

Operation Inspection

Lists pre-operation checks to ensure safe and correct system setup.

Inspection before operation

Details specific checks required before the initial startup of the unit.

Inspection of operation status

Describes how to monitor and check the unit's performance during operation.

Overall Nozzle Dimensions during Module Combination

Table showing nozzle dimensions based on the number of modules combined.

Calculations of Water System Inventory

Guides on calculating the necessary water capacity for the system.

Type Selection of Auxiliary Electric Heater

Provides recommendations for selecting auxiliary heaters for specific conditions.

Connection diagram of the unit power cords

Illustrates the wiring connections for the unit's power supply cords.

Electrical parameters

Table listing essential electrical specifications for different unit models.

Address Code Setting (SW401)

Instructions for setting the address codes for modular units.

Requirements for Communication Wires

Specifies the standards and characteristics for communication cables.

Connection of Communication Wires

Shows the wiring diagram for connecting communication wires between units.

Maintenance

Inspection and cleaning of condenser

Procedure for inspecting and cleaning the unit's condenser fins.

Inspection and cleaning of heat exchanger

Steps for checking and cleaning the water-side heat exchanger.

Make-up of refrigerant and lube oil

Information regarding refrigerant and lube oil levels and replenishment.

Fault Code

List of error codes, their descriptions, and remarks for troubleshooting.

Common Faults and Troubleshooting

Details common operational issues and their corresponding solutions.

Technical Parameters

Performance Parameters

Table summarizing key performance specifications for various unit models.

Correction factor

Provides correction factors for performance based on operating conditions.

Operation Instructions

Unit Service Conditions

Defines the operating range and conditions for the chiller unit.

Move and scrap the air conditioning

Warranty Declaration

Haier CA0035EAND Specifications

General IconGeneral
BrandHaier
ModelCA0035EAND
CategoryChiller
LanguageEnglish

Related product manuals