Functions and control
21
Domestic air conditioner
11ć
9ć
Increasing slowly
9ć
Keeping the frequency
7ć
5ć 7ć Decreasing slowly
3ć 5ć Decreasing rapidly
1ć Stop
The compressor stops for more than 3 minutes, Tpg_indoor> 9ć, the compressor recovers.
7.2 Value of Thermistor
Ambient Sensor, Defrosting Sensor, Pipe sensor
R25ć=10K¡f3% B25ć/50ć=3700Kf3%
Temp.(ć)
Max.(Kȍ) Normal(Kȍ) Min.(Kȍ)
Tolerance(ć)
-30 165.2170 147.9497 132.3678 -1.94 1.75
-29 155.5754 139.5600 125.0806 -1.93 1.74
-28 146.5609 131.7022 118.2434 -1.91 1.73
-27 138.1285 124.3392 111.8256 -1.89 1.71
-26 130.2371 117.4366 105.7989 -1.87 1.70
-25 122.8484 110.9627 100.1367 -1.85 1.69
-24 115.9272 104.8882 94.8149 -1.83 1.67
-23 109.4410 99.1858 89.8106 -1.81 1.66
-22 103.3598 93.8305 85.1031 -1.80 1.64
-21 97.6556 88.7989 80.6728 -1.78 1.63
-20 92.3028 84.0695 76.5017 -1.76 1.62
-19 87.2775 79.6222 72.5729 -1.74 1.60
-18 82.5577 75.4384 68.8710 -1.72 1.59
-17 78.1230 71.5010 65.3815 -1.70 1.57
-16 73.9543 67.7939 62.0907 -1.68 1.55
-15 70.0342 64.3023 58.9863 -1.66 1.54
-14 66.3463 61.0123 56.0565 -1.64 1.52
-13 62.8755 57.9110 53.2905 -1.62 1.51
-12 59.6076 54.9866 50.6781 -1.60 1.49
-11 56.5296 52.2278 48.2099 -1.58 1.47
-10 53.6294 49.6244 45.8771 -1.56 1.46
-9 50.8956 47.1666 43.6714 -1.54 1.44