Service diagnosis
34
Domestic air conditioner
10.4.2 EEPROM abnormal
Indoor Display E4: indoor EEPROM error
Indoor display F12: Outdoor EEPROM error; Outdoor LED1 flash 1 times
Method of The Data detected by the MCU are used to determine MCU
Malfunction
Malfunction when the data of EEPROM is error or the EEPROM is damaged
Decision
Ŷ Faulty EEPROM data
Ŷ Faulty EEPROM
Ŷ Faulty PCB
Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or
parts damage may be occurred.
10.4.4 Outdoor DC fan motor fault
Outdoor display F8˖LED1 flash 9 times
DC fan motor is detected by checking the fan running condition and so on
Ƶ DC fan motor protection dues to the DC fan motor faulty
Ƶ DC fan motor protection dues to faulty PCB
* Caution Be sure to turn off power switch before connect or disconnect connector, or parts damage
may be occurred.
Replace the indoor or outdoor mainboard
Method of
Malfunction
Malfunction
Detection
Conditions
Troubleshooti
ng
Supposed
Causes
Method of
Malfunction
Malfunction
Detection
Conditions
Troubleshooti
ng
Supposed
Causes