SERVICE MANUAL
Model: HB21FC45N*
39
Issue 2010-07-05
Rev. Ref1007S019V0
9-4. The error code
9-4-1.When the refrigerator sensor (R SNR) is in malfunction, it shows F1 on cabinet
display panel.
How to check:
1. Check whether the connector of main control PCB is in right position.
2.Test the resistance between two white wire(CON1), the normal resistance should be 16K ohm
approximately, if the ohm number is infinite or zero, it means the sensor or the connecting wire is
defective.
9-4-2. When the ambient temperature sensor (RT SNR) is in malfunction, it shows F3 on
cabinet display board.
How to check:
1. Check whether the connector of main control PCB is in right position;
2. Test the resistance between two white wires(CON5), the normal resistance should be 16K ohm
approximately, if the ohm number is infinite or zero, it means the sensor or the connecting wire is
defective.