SERVICE MANUAL
Model: HB21FC45N*
41
Issue 2010-07-05
Rev. Ref1007S019V0
9-4-4. When the defrost sensor (D SNR) is in malfunction, it shows F5 on cabinet display
board.
How to check:
1.
Take down the fan cover and fan motor, check whether the connector of defrost sensor is in right
position; ensure the wire connector is in good connecting status.
2.Disconnect the connector, test the resistance between two black wires, the normal resistance should be
1~30K ohm approximately, if the ohm number is infinite or zero, it means that the sensor is defective.
If the sensor is normal, reconnect the connector.
3.
Check whether the connector of main control PCB is in right position.
4.Test the resistance between two red wires(CON4), the normal resistance should be 1~30K ohm
approximately, if the ohm number is infinite or zero, it means that the connecting wire in cabinet is
defective.