SLEEP
operation starts
SLEEP
operation stops
1 hr
1 hr
3 hrs
3 hrs
Rises 1
O
C
Temp.setting
Unit stop
In HEAT mode
Decreases 2
O
C
Decreases 2
O
C
SLEEP operation starts SLEEP operation stops
Approx.6hrs
1 hr
Rises 1
O
C
Rises 1
O
C
Temp.setting
Unit stop
In COOL, DRY mode
1 hr
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
TIMER OFF-ON
0.5h
0.5h 0.5h
0.5h
Operation
  Sleep Operation
Press    button to enter additional options.  
When display cycles to   
 ,   will   
Then press 
 to enter sleep function.
1. Operation Mode 
In COOL, DRY mode 
1 hour after SLEEP mode starts, the temperature will become 1°C higher  
than the temperature setting. After another hour the temperature rises by
another 1°C. The unit will run for a further 6 hours. The temperature is higher
than the temperature setting, so that the room temperature won’t be too
 
cold
 
for you to sleep.
2.  In HEAT mode 
1 hour after SLEEP mode starts, the temperature will become 2°C lower
 
than
 
the temperature setting. After another hour, the temperature decreases by
 
a
 
further 2°C. After another 3 hours, the temperature will rise by another 1°C.
 
The
 
unit will run for a further 3 hours. The temperature is lower than the temperature
 
setting, so that the room temperature won’t be too hot for you to sleep.
3. In AUTO mode 
The unit operates in the corresponding sleep mode for the automatically
 
selected operation mode.
4.  In FAN mode 
The SLEEP function does not operate in FAN mode.
5.  Set the fan speed change when sleeping 
If the fan speed is high or medium, you can set it to lower the fan 
speed after you go to sleep. If it is already set at low fan speed,  
it is unchanged.
Note
When the TIMER function is set, the sleeping function can’t be 
set up. After the sleep function is set up, if you reset the 
TIMER function, the sleep function will be cancelled.
  Timer On-Off Operation
1.  After unit starts, select your desired operation mode.
2.  Press the TIMER button to change to TIMER mode. Every time the button is 
pressed, the display changes as follows: 
Remote controller: 
Then select your desired TIMER mode (TIMER ON or TIMER OFF or TIMER 
ON-OFF). “ON“ or “OFF“ will 
3. Press  T / S button to set the time. 
 
SPress the button for each time, setting time in the 
 12 hours increased  
 by 0.5 hour every time and after 12 hours, increased by 1 hour every time. 
 
T  Press the button for each time, setting time in the 
 12 hours 
  decreased  by 0.5 hour every time and after 12 hours, decreased by  
 1 hour  every time.  It can be adjusted within 24 hours.
4. 
 timer setting 
After adjusting the time, press the   
 button and   the time. The 
ON or OFF button will not 
 any more.
5.  Cancel timer setting 
Press the timer button repeatedly until the time display does not show.
Hints:
After replacing batteries or a power failure, the time setting should be reset. 
DRED Operation 
Haier Peaksmart enabled air-conditioners have a Demand Response Mode display
 on the indoor unit.  
The display could be labelled d1, d2, d3 (wording may differ model to model). 
These modes are described in more detail below:  
 od ot tahW noitpircseD yalpsiD edoM
DRM3 d3 
Your air-conditioner will continue 
to cool or heat during the peak 
demand event. The energy 
consumed by your air-conditioner 
is capped to 75%. 
 No action is required. 
DRM2 d2 
Your air-conditioner will continue 
to cool or heat during the peak 
demand event. The energy 
consumed by your air-conditioner 
is capped to 50%. 
 No action is required. 
DRM1 d1 
Your air-conditioner is still tuned 
on and the fan will continue to 
operate. Your compressor is 
turned off and cool/hot air will no 
longer be generated 
DRM1 mode is only activated during 
emergency demand management 
situations.   This mode will automatically reset 
the device within 2 hours .If your air-con is in 
this mode for longer than 2 hours please 
contact Energex on 13 12 53. 
 
 
(This function is unavailable on some models.) 