INSTALLATION
PAGE 8
ENGLISH
Model Name
Outdoor HSU09VHG(DB)-W HSU12VHG(DB)-W HSU18VHH(DB)-W HSU24VHG(DB)-W
Indoor HSU09VHG(DB)-G HSU12VHG(DB)-G HSU18VHH(DB)-G HSU24VHG(DB)-G
Operating Range
Cooling °F(°C) 41~115(5~46) 41~115(5~46) 41~115(5~46) 41~115(5~46)
Heating °F(°C) 5~75(-15~24) 5~75(-15~24) 5~75(-15~24) 5~75(-15~24)
Power Supply Voltage/Frequency/Phase V/Hz/- 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1
Compressor Compressor Type DC Inverter Driven Rotary
Electrical Data
Maximum Fuse Size A 15 15 20 25
Minimum Circuit Amp A 12 14 17 19
Refrigerate Line
Connections Flare Flare Flare Flare
Liquid O.D. in 1/4 1/4 1/4 3/8
Suction O.D. in 3/8 3/8 1/2 5/8
Factory Charge Refrigerant/Oz R410A/35.3 R410A/38.1 R410A/54.7 R410A/74.1
Maximum Line Length Ft / m 50/15 50/15 83/25 83/25
Maximum Height Ft / m 33/10 33/10 50/15 50/15
Using the OPERATING INSTRUCTIONS, explain to the user how to use the air conditioner (the remote controller, removing
the air lters, placing or removing the remote controller from the remote controller holder, cleaning methods, precautions for
operation, etc.)
Recommend that the user read the OPERATING INSTRUCTIONS carefully.
Section 7 - Explaining Operation to the End User
Section 8 - System Specications
Section 9 - Seacoast Application
The outdoor unit should be installed at least ½ mile away from the salt water, including seacoasts and inland waterways. If
the unit installed from ½ mile to 5 miles away from the salt water, including seacoasts and inland waterways, please follow the
installation instruction below.
ODU
ODU
Sea breeze
Sea
ODU
Sea breeze
Sea
ODU
Sea breeze
Sea
Protecti on walls
ODU
Install the outdoor unit in a place (such as near buildings etc.) where it can be protected from sea breeze which can damage
the outdoor unit.
If you cannot avoid installing the outdoor unit by the seashore, construct a protection wall around it to block the sea breeze.
A protection wall should be constructed with a solid material such as
concrete to block the sea breeze and the height and the width of the wall
should be 1.5 times larger than the size of the outdoor unit. Also, secure
over 28 in (700mm) between the protection wall and the outdoor unit for
exhausted air to ventilate.
Install the outdoor unit in a place where water can drain smoothly.
If you cannot nd a place satisfying above conditions, please contact manufacturer. Make sure to clean the sea water and the
dust on the outdoor unit heat exchanger.

Other manuals for Haier HSU09VHGDB-W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haier HSU09VHGDB-W and is the answer not in the manual?

Haier HSU09VHGDB-W Specifications

General IconGeneral
BrandHaier
ModelHSU09VHGDB-W
CategoryAir Conditioner
LanguageEnglish

Related product manuals