HSU09VHJ˄DB˅-SM  
Funcitions and Control 
Domestic Air Conditioner
14
5.Funcitions and Control
5.1 Main functions and control specification of indoor unit
This specification use for HSU18VHJ˄DB˅frequency conversion air condition are manufactured 
by Haier air condition parent company. "Setting value" (express in parameter) in this specification 
means is a parameter that is stored in EEPROM. Refer to [EEPROM parameter table].
5.1.1 Temperature Adjusting function 
5.1.1.1 Temperature adjusting of different levels.   
(DASH operation conditions under different modes) 
5.1.1.2 Select the wind volume when it is set automatic 
When the wind volume is automatic, it can be switched between strong, medium and weak according 
to the temperature adjusting levels. 
Wind volume under the automatic wind volume mode 
Temperature adjusting levels 
A B C D E F G H  I 
Heating 
Strong Strong  Strong Strong Strong Medium Weak Weak  SLO 
cooling
 Strong Strong Strong Medium Medium Weak Weak Weak 
Moisture
removing 
 Strong Medium Medium Medium Weak  Weak SLO  SLO 
&22/
+($7'$6+
%
0,187(63527(&7,21
&22/'$6+
'5<'$6+
7
 
&20367$576$*$,1
(
*
)
+
'
&
&22/'5< +($7
(
%/2&.
$
+($7
'5<
V