EasyManua.ls Logo

Haier HSU09VHJ - Page 56

Haier HSU09VHJ
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HSU09VHJ˄DB˅-SM
Service Diagnosis
Domestic Air Conditioner
54
Method of IPM protection is detected by checking the compressor running condition and so on.
Malfunction
Detection
Malfunction
Ƶ
The system leads to IPM protection due to over current
Decision
Ƶ
The compressor faulty leads to IPM protection
Conditions
Ƶ
circuit component of IPM is broken and led to IPM protection
Supposed
Ƶ
IPM protection dues to the compressor faulty
Causes
Ƶ
IPM protection dues to faulty PCB of IPM module
Ƶ
Compressor wiring disconnected
Troubleshooting
* Caution
Be sure to turn off power switch before connect or disconnect connector, or
else parts damage may be occurred.
Check the IPM module method:
Disconnect the compressor harness connector from the outdoor unit PCB.
To disengage the connector, press the protrusion on the connector.
Then, to measure resistance between P (+) andN (-) and the U, V and W terminals of the
compressor connector with a multi-tester. Evaluate the measurement results for a
pass/fail judgment.
N(-)terminal of tester(P(+)for digital
tester)
P(+) UVW P(-) UVW
P(+)terminal of tester(N(-)for digital
tester)
UVW P(+) UVW P(-)
Normal resistance
Several k to several M (и)
Unacceptable resistance Short (0 ) or open
Turn off the power.check if
the compressor wiring
NO
Check the IPM module
Yes
Normal
Yes
NO
Test the resistance values among
Phases U, V and W of com
p
ressor
If the resistance
are e
q
ual and less
NO
Yes
Check the installation condition
.
Change the IPM module
Renewedly connect the wiring
Replace the compressor