Outdoor display:   LED1  flash  6 times   The power supply is over voltage 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Method of      
An abnormal voltage rise or fall is detected by checking the specified voltage detection circuit.
 
Malfunction      
 
Detection 
 
Malfunction     
An voltage signal is fed from the voltage detection circuit to the microcomputer   
Decision 
Conditions  
 
 
Supposed         ■ 
  Supply voltage not as specified 
Causes           ■ 
the IPM module is broken         
■  
the outdoor PCB is broken 
 
Troubleshooting    
* Caution   
Be sure to turn off power switch before connect or disconnect connector, or else 
parts damage may be occurred. 
 
 
 
 
Electrify the machine again and turn it on with 
the remote controller. Check whether the 
compressor is started normally 
Is it ok? 
Yes 
Maybe there is some disturbance 
NO 
No 
~230 is ok? 
Yes 
Yes 
This question may be caused by the power. Repair 
the power supply. 
NO 
Change the IPM module 
 
Change the IPM module 
 
Test the outdoor power supply 
(+310VDC) with a multimeter. 
check whether the power 
is >150 V or <390V? 
50