Drawing for the installation of indoor and outdoor units
Necessary Tools for Installation
Torque wrench
(17mm,22mm,26mm)
Nipper
Reamer
Hacksaw
Pipe cutter
Gas leakage detector or
soap-and-water solution
Hole core drill
Flaring tool
Spanner wrench(17,19 and 26mm)
Knife
Measuring tape
Selection of Installation Place
Power Source
Preparation
The above picture is for reference only. Your product may look different.
Read this manual before installation
Explain the operation of the unit to the user according to this manual
NO.0010564641
Installation Manual of Room Air Conditioner
Optional parts for piping
Non-adhesive tape
Adhesive tape
Saddle (L.S) with screws
Connecting electric cable
for indoor and outdoor
Drain hose
Insulating material
Piping hole cover
Floor xing dimensions of the outdoor unit
Fixing of outdoor unit
Fix the unit to concrete or block
with bolts
(2/5 in.) securely.
When
tting the unit to wall
surface, roof or
rooftop,
x the unit securely in consideration
of
earthquake and strong wind.
If vibration may affect the
house, xtheunit
by attaching a
vibration-proof mat.
The models use HFC free refrigerant R410A
A
F
C
E
D
G
B
XYX
Z
Dimensions(mm/inches)
Model
xyz
583
319.5
HSU218VHG-W
Hammer
Place where the distance of more than 3 ft from televisions, radios, wireless apparatuses
and
uorescent lamps 3 feet or approximately.
In the case of xing the remote controller on a wall, place where the indoor unit can
receive signals when the
uorescent
lamps in the room are in use.
A distance marked is available as illustrated in the below gure.
Indoor Unit - Select a location that is
Outdoor Unit - Select a location that is
Robust not causing vibration, where the unit can be supported satisfactorily.
Not affected by heat or steam generated in the vicinity, and where the inlet and outlet of
the unit are not disturbed.
Possible to drain easily, and where piping can be connected with the outdoor unit.
Where conditioned air can be spread in a room evenly.
tilated.
Strong enough base to bear the unit, where vibration and noise are not increased.
That is easily accessible for maintenance or service.
(Unit:mm / inch)
(4 1/2)
113.5
(23)
(12 5/8)
All wiring to the unit must be in accordance with the National Electric code
and local ordinances.
The marks from to
in the
gure are the
Part Numbers.
Thedistancebetween
theindoorunitandthe
oorshouldbemore
than 6 ft.
more than
10cm
more than 15 cm
more than 10cm
more than 20cm
more than 15cm
more than
60cm
A
Indoor unit A
Indoor unit B
F
C
G
Arrangement of piping
directions
Rear left
Left
Rear
right
Right
Below
Attention must be paid to
the downward angle up
of drain hose
E
D
more than 20cm
(6 in.)
(4 in.)
(4 in.)
(8 in.)
(8 in.)
(24 in.)
(6 in.)
Domestic Air Conditioner

Installation