9
Vacuum Check
During suction, the gauge indicating sucking status is shown at the lower side
of the screen.
When “CHK” appears and you notice that the sucking force is weakening,
perform “Vacuum Check.”
1.
Move the cursor to select “Vacuum Check”. After selecting, press <ENT>.
2.
Pull the trigger.
3. When “Clogging” appears, perform cleaning and replace filters.
F
Suction gauge Sign of clogging
CHK
<↑> <↓> <ENT>
Se t Temp
O f f s e t T emp
V acuum Check
680 F
00 F
<EXIT>
V acuum Check
P u ll T r i gge r
<EXIT>
V acuum Check
P u ll T r i gge r
O K
<EXIT>
V acuum Check
P u ll T r i gge r
Clo g gin g
No degradation in sucking force Degradation in sucking force
10
Preset Temp
1. Move the cursor to select “Preset Temp”. After selecting, press <ENT>.
Select the preset No. whose temperature setting you wish to change.
2.
Entering from hundreds to units digit
Press the <> or <> to set the desired figure.
Only values from 6 to 8 can be selected when entering the hundreds digit.
(In mode, values from 3 to 4 can be selected.)
Values from 0 to 9 can be selected when entering the tens or units digits.
(The same values can be selected in mode.)
3. After entering the units digit, press the button to save the figure to the system
memory and begin heater control with new setting temperature.
4. To exit from each setting screen, scroll the screen, select <EXIT>, and press the
<ENT> button.
CAUTION
If power is switched off or lost during the execution of this procedure, no data
will be entered. The entire procedure must be repeated from step 1.
<↑> <↓> <ENT>
O f f s e t T emp
V acuum Check
P r ese t Temp
00 F
SelectthepresetNo.
<↑> <↓> <ENT>
P1 Temp
P2 Temp
P3 Temp
660 F
750 F
840 F
<↑> <↓> <ENT>
PRESET1 TempS e t
60 F
<↑> <↓> <ENT>
PRESET1 TempS e t
6 0 F
<↑> <↓> <ENT>
PRESET1 TempS e t
66
F
<↑> <↓> <ENT>
P2 Temp
P3 Temp
<EXIT>
750 F
840 F
CAUTION
The temperature range is from 620 to 850℉. (330 to 450℃)
If you enter a value outside the temperature setting range, the display returns to
the hundreds digit, and you have to enter a correct value.