TECHNICAL SPECIFICATIONS
2
2.1
GAS CATEGORIES
2.2
PERFORMANCE DATA
Appliance Ace HE24 Ace HE30 Ace HE35
Mode Rate
Central Heating Output Max
kW 18.0 23.1 24
(non-condensing)
(Btu/h) (61500) (78900) (81900)
(80 - 60 °C)
Min
kW 6.0 7.2 8.3
(Btu/h) (20500) (24600) (28300)
Central Heating Output (condensing)
Max
kW 19.7 25.4 26
(50 - 30 °C) (Btu/h) (67300) (86700) (88700)
Net
kW 18.4 23.9 24.5
Central Heating Input
(Btu/h) (62800) (81600) (83600)
Max Rate
Gross
kW 20.4 24.8 27.2
(Btu/h) (69700) (84700) (92800)
Net
kW 5.6 6.9 8.5
Central Heating Input
(Btu/h) (19100) (23600) (29000)
Min Rate
Gross
kW 6.2 7.5 9.4
(Btu/h) (21200) (25600) (32100)
Domestic Hot Water Output Max
kW 24.0 30.0 35.0
(Btu/h) (82000) (102400) (119400)
Min
kW 6.0 7.2 8.3
(Btu/h) (20500) (24600) (28300)
Net
kW 24.6 31.3 35.7
Domestic Hot Water Input
(Btu/h) (84000) (106900) (121800)
Max Rate
Gross
kW 27.3 34.8 39.6
(Btu/h) (93200) (118900) (135200)
Net
kW 5.6 6.9 8.5
Domestic Hot Water Input
(Btu/h) (19100) (23600) (29000)
Min rate
Gross
kW 6.2 7.5 9.4
(Btu/h) (21200) (25600) (32100)
Central Heating Gas Rate
m3/h 1.95 2.49 2.59
(after 10 min operation - hot)
Max
ft3/h (68.9) (87.9) (91.5)
Domestic Hot Water Gas Rate
m3/h 2.6 3.31 3.78
(after 10 min operation - hot)
Max
ft3/h (91.8) (116.9) (133.5)
Seasonal Efficiency % 90.1 90.1 90.1
Seasonal Efficiency (SEDBUK) Band “A”
Nox Classification Class “5”