Hanna Instruments GroLine HI9814 Specifications

General IconGeneral
ModelHI9814
CategoryMeasuring Instruments
ManufacturerHanna Instruments
Product LineGroLine
pH Range0.00 to 14.00 pH
pH Resolution0.01 pH
EC Range0.00 to 20.00 mS/cm
EC Resolution0.01 mS/cm
TDS Resolution1 ppm
TDS Accuracy±2% F.S.
Temperature Resolution0.1 °C
Temperature Accuracy±0.5 °C
IP RatingIP67
TypepH/EC/TDS Meter
CalibrationAutomatic, 1 or 2 points
Battery Type1.5V AAA (4)

Summary

Preliminary Examination

Package Contents

Lists all items included with the meter, such as probes and solutions.

General Description and Intended Use

Meter Overview

Describes the meter's durability, portability, and IP67 rating for rugged use.

Main Features

Display Description

LCD Display Elements

Details the function of each numbered segment on the meter's LCD screen.

Specifications

Operational Guide

Connecting the Probe

Instructions on how to attach the HI1285-7 probe to the meter.

Turning the Meter On

Steps to power on the meter, including battery check.

Meter Setup

Temperature Unit Selection

Configures the display unit for temperature (°C or °F).

Auto-off Configuration

Sets the time delay before the meter automatically powers off.

Calibration Type Selection

Chooses between standard (STD) or quick (QUICK) calibration.

TDS Conversion Factor

Selects the factor for converting conductivity to TDS (0.50 or 0.70).

Calibrations

pH Calibration

Procedure for calibrating the pH measurement using standard or quick methods.

Single-Point Calibration

Steps for calibrating with a single buffer solution.

Two-Point Calibration

Procedure for calibrating using two different buffer solutions.

EC Calibration

Procedure for calibrating the EC measurement using standard solutions.

Battery Replacement

Accessories

Electrode Maintenance

Preparation and Storage

Instructions for cleaning, soaking, and storing the electrode.

Cleaning Procedure

Detailed steps for cleaning the electrode using specific solutions.

Troubleshooting

Guidance for resolving common issues with the meter and electrode.

Certification and Disposal

Recommendations and Warranty

User Recommendations

Advice on suitable applications and environmental considerations for meter use.

Warranty Information

Details on the product warranty period and conditions for repair or replacement.