www.hannainst.com
WARRANTY
HI 98129 and HI 98130 are warranted for one
year against defects in workmanship and materials
when used for their intended purpose and maintained
according to instructions. The electrode is war-
ranted for a period of six months. This warranty is
limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack
of prescribed maintenance are not covered.
If service is required, contact the dealer from whom
you purchased the instrument. If under warranty,
report the model number, date of purchase, serial
number and the nature of the failure. If the repair is
not covered by the warranty, you will be notified of
the charges incurred. If the instrument is to be re-
turned to Hanna Instruments, first obtain a Returned
Goods Authorization Number from the Customer
Service department and then send it with shipment
costs prepaid. When shipping any instrument, make
sure it is properly packaged for complete protection.
All rights are reserved. Reproduction in whole or in
part is prohibited without the written consent of the
copyright owner, Hanna Instruments.
Instruction Manual
HI 98129 • HI 98130
pH/EC/TDS/Temperature
with Only One Tester
Dear Customer,
Thank you for choosing a Hanna product.
This manual will provide you with the necessary
information for a correct operation. Please read it
carefully before using the meter.
If you need additional technical information, do not
hesitate to e-mail us at tech@hannainst.com.
These instruments are in compliance with the
directives.
Remove the instrument from the packing material and
examine it carefully. If any damage has occurred
during shipment, immediately notify your Dealer or
the nearest Hanna Customer Service Center.
Each meter is supplied with:
HI 73127 pH electrode
HI 73128 electrode removal tool
• batteries (4 x 1.5V) and instructions
Note: Conserve all packing material until the instru-
ment has been observed to function correctly.
Any defective item must be returned in its
original packing.
PRELIMINARY EXAMINATION
HI 98129 and HI 98130 are waterproof pH/EC/
TDS/temperature meters. The housing has been com-
pletely sealed against humidity and designed to float.
All pH and EC/TDS readings are automatically tem-
perature compensated (ATC), and temperature values
can be displayed in °C or °F units.
For EC/TDS readings, the EC/TDS conversion factor
(CONV) is selectable by the user, as well as the
temperature compensation coefficient β (BETA).
The meters can be calibrated at one or two points for
pH (with auto-buffer recognition and against five
memorized buffer values), and at one point for EC.
Measurements are highly accurate with a unique
stability indicator right on the LCD.
These meters are also provided with battery level
indication at start-up, and with a low battery symbol
which warns the user when the batteries need to be
replaced. In addition the Battery Error Prevention
System (BEPS) avoids erroneous reading caused by low
voltage level by turning the meter off.
The HI 73127 pH electrode, supplied with the meter,
is interchangeable and can be easily replaced by the
user.
The stainless steel encapsulated temperature sensor
facilitates faster and more accurate temperature mea-
surement and compensation.
GENERAL DESCRIPTION
FUNCTIONAL DESCRIPTION SPECIFICATIONS
Recommendations for Users
Before using this product, make sure that it is entirely suit-
able for the environment in which it is used. Operation of
this instrument in residential areas could cause unaccept-
able interferences to radio and TV equipment.
The glass bulb at the end of the electrode is sensitive to
electrostatic discharges. Avoid touching this glass bulb at
all times.
Any variation introduced by the user to the supplied equip-
ment may degrade the instrument’s EMC performance. To
avoid electrical shock, do not use this instrument when volt-
ages at the measurement surface exceed 24 Vac or 60 Vdc.
To avoid damages or burns, do not perform any measure-
ment in microwave ovens.
IST98129R4 07/05
Range
Resolution
Accuracy
(@20°C/68°F)
Typical EMC
Deviation
Temperature
Compensation
Environment
TDS Factor
Calibration
EC/TDS Cal.solutions
HI 98129:
HI 98130:
Electrode (included)
Battery Type/Life
Auto-off
Dimensions
Weight
0.0 to 60.0°C / 32.0 to 140.0°F
0.00 to 14.00 pH
0 to 3999 µS/cm (HI 98129)
0.00 to 20.00 mS/cm (HI 98130)
0 to 2000 ppm (HI 98129)
0.00 to 10.00 ppt (HI 98130)
0.1°C / 0.1°F
0.01 pH
1 µS/cm ; 1 ppm (HI 98129)
0.01 mS/cm ; 0.01 ppt (HI 98130)
±0.5°C / ±1°F
±0.05 pH
±2% f.s. (EC/TDS)
±0.5°C / ±1°F
±0.02 pH
±2% f.s. (EC/TDS)
automatic,
with β=0.0 to 2.4%/ºC (EC/TDS)
0 to 50°C (32 to 122°F); RH 100%
0.45 to 1.00 (CONV)
automatic, 1 or 2 point with 2 sets of
memorized buffers (pH 4.01/7.01/
10.01 or 4.01/6.86/9.18) for pH;
automatic, at 1 point for EC/TDS
HI7031 (1413 µS/cm)
HI7032 (1382 ppm; CONV=0.5)
HI70442 (1500 ppm; CONV=0.7)
HI7030 (12.88 mS/cm)
HI70038 (6.44 ppt; CONV=0.5
or 9.02 ppt; CONV=0.7)
HI 73127 pH electrode
4 x 1.5V with BEPS/approx. 100 hours
after 8 minutes of non-use
163 x 40 x 26 mm (6.4 x 1.6 x 1.0”)
100 g (3.5 oz.)
1. Battery compartment
2. Liquid Crystal Display (LCD)
3. ON/OFF/MODE button
4. HI 73127 pH electrode
5. Temperature sensor (behind)
6. EC/TDS probe
7. SET/HOLD button
1. Automatic temperature compensation indicator
2. Stability indicator
3. Battery life percentage indicator
4. Low battery indicator
5. Secondary display
6. Primary display
7. Measuring units for primary display
US DESIGN PATENT
D462,024
Hanna Instruments reserves the right to modify the design, con-
struction and appearance of its products without advance notice.
Question and Answer IconNeed help?

Do you have a question about the Hanna Instruments HI 98129 and is the answer not in the manual?

Hanna Instruments HI 98129 Specifications

General IconGeneral
pH Range0.00 to 14.00 pH
pH Resolution0.01 pH
pH Accuracy±0.01 pH
EC Range0 to 3999 µS/cm
EC Resolution1 µS/cm
EC Accuracy±2% F.S.
TDS Resolution1 ppm
TDS Accuracy±2% F.S.
Temperature Resolution0.1 °C
Temperature Accuracy±0.5 °C
EC Calibration1 point
Battery Type4 x 1.5V AAA
IP RatingIP67
TypepH/EC/TDS Meter
CategoryPortable Meter
TDS Range0 to 2000 ppm
Temperature Range0.0 to 60.0°C
pH Calibration1 or 2 point with automatic recognition

Summary

Instruction Manual HI 98129 HI 98130 pH/EC/TDS/Temperature with Only One Tester

Preliminary Examination

Instructions for examining the instrument upon receipt and its contents.

Warranty Information

Details the one-year warranty for the instrument and six-month warranty for the electrode.

General Description

Overview of the waterproof pH/EC/TDS/temperature meter features and capabilities.

Functional Description

Identifies and describes the main components and parts of the HI 98129/HI 98130 tester.

Specifications

Lists the technical specifications, including range, resolution, accuracy, and environmental conditions.

Recommendations for Users

Provides user recommendations for safe and accurate operation and environmental considerations.

Operational Guide

Turning On and Battery Check

Instructions on how to turn the meter on and check the remaining battery life percentage.

Changing Temperature Unit

Procedure to switch between Celsius (°C) and Fahrenheit (°F) temperature units.

Freezing the Display

How to freeze the current measurement displayed on the LCD.

Turning Off the Meter

Instructions on how to properly turn off the instrument.

pH Measurements and Calibration

Taking pH Measurements

Steps for taking pH measurements, including submerging the electrode and waiting for stability.

pH Calibration Procedure

Step-by-step guide for calibrating the pH meter, including single and two-point calibration.

EC/TDS Measurements and Calibration

Taking EC/TDS Measurements

Procedure for taking EC/TDS measurements, including probe submersion and stability waiting.

Adjusting EC/TDS Conversion and Compensation

How to adjust the EC/TDS conversion factor and temperature compensation coefficient.

EC/TDS Calibration Procedure

Procedure for calibrating the EC/TDS meter using calibration solutions.

pH Electrode Maintenance and Replacement

pH Electrode Care

Instructions for electrode storage, reactivation, cleaning, and general maintenance.

pH Electrode Replacement

Step-by-step guide for safely removing and replacing the pH electrode using the provided tool.

Battery Replacement

Battery Replacement Procedure

Instructions on how to replace the meter's batteries, including access and proper seating.

Accessories

Available Accessories

List of optional accessories and consumables for the HI 98129/HI 98130 testers.