12
The temperature has an effect on pH. The calibration buffer solutions
are affected by temperature changes to a lesser degree than normal
solutions. During calibration the instrument will automatically calibrate
to the pH value corresponding to the measured or set temperature.
During calibration the instrument will display the pH buffer value at
25 °C.
pp
pp
p
H BUFFER TEMPERATUREH BUFFER TEMPERATURE
H BUFFER TEMPERATUREH BUFFER TEMPERATURE
H BUFFER TEMPERATURE
DEPENDENCEDEPENDENCE
DEPENDENCEDEPENDENCE
DEPENDENCE
PMETSREFFUBHp
CºFº10.468.610.781.910.01
023 10.489.631.764.923.01
514 00.459.601.793.942.01
0105 00.429.670.733.981.01
5195 00.409.650.772.921.01
0286 00.488.630.722.960.01
5277 10.468.610.781.910.01
0368 20.458.600.741.969.9
5359 30.448.699.611.929.9
04401 40.448.689.670.988.9
54311 50.438.689.640.958.9
05221 60.438.689.610.928.9
55131 80.448.689.699.897.9
06041 90.448.689.679.877.9
56941 11.448.699.659.867.9
07851 21.458.699.639.857.9
57761 41.468.600.719.847.9
08671 61.478.610.798.847.9
58581 71.478.620.778.847.9
09491 91.488.630.758.857.9
59302 02.498.640.738.867.9
17
mode tags
battery
symbol
calibration
messages
first or second
calibration point
temperature reading
or pH buffer value
pH or mV
measurement
available keys
in accordance with
the selected mode
TAGS & SYMBOLS
Mode tags light up for indicating the corresponding active mode,
and blink for warning the user.
MEASURE on: measurement mode.
CALIBRATION on: calibration mode has been entered.
MEMORIZE on: measurement stored in the internal memory and
frozen on the display
RECALL MEMORIZED on: stored value recalled.
Battery symbol blinking: low battery condition. Batteries should
be recharged.
Calibration messages.
WAIT NOT READY blinking: buffer has been recognized, but
reading is not stable.
READY on: buffer has been recognized and reading is stable.
WRONG and WRONG blinking alternatively: wrong
buffer, value not recognized.
LCD MESSAGE GUIDELCD MESSAGE GUIDE
LCD MESSAGE GUIDELCD MESSAGE GUIDE
LCD MESSAGE GUIDE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hanna Instruments HI 9125 and is the answer not in the manual?

Hanna Instruments HI 9125 Specifications

General IconGeneral
BrandHanna Instruments
ModelHI 9125
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals