Summary of general specifications including conductor diameter, indicators, temperature ranges, battery details, weight, dimensions, and output.
Defines the effective ranges for DC and AC current measurements for the probe.
Details system accuracy and probe accuracy for DC and AC current measurements.
Summary of general specifications including conductor diameter, indicators, temperature ranges, battery details, weight, dimensions, and output.
Defines the effective ranges for DC and AC current measurements for the probe.
Details system accuracy and probe accuracy for DC and AC current measurements.
The Hantek CC-650 AC/DC Current Probe is a versatile tool designed for measuring both DC and AC currents up to 650A and 500A respectively, with a measurement frequency up to 5KHz. This probe allows for non-invasive current measurement, eliminating the need to break the current loop or strip insulation from conductors. Its design, featuring an extended jaw, makes it suitable for measurements in confined spaces.
The CC-650 current probe enables multimeters and oscilloscopes to directly measure current. When connected to a multimeter, the BNC/banana-KJJ adapter is used, with the GND terminal inserted into the COM terminal and the other terminal into the V-Ω terminal. It's crucial that the multimeter's input impedance is at least 10K ohms. For oscilloscope connections, the probe's BNC plug connects directly to the oscilloscope's BNC terminal.
The probe offers two measurement ranges: 10mV/A and 1mV/A, selected via a slider switch. A green power indicator lights up when the probe is powered normally. For currents not exceeding 20 amperes, the 10mV/A range is recommended, paired with the AC 200mV or DC 200mV range on the multimeter.
A critical feature for DC current measurement is the zero adjustment knob. Before measuring, especially DC current, the user must rotate this knob until the multimeter reading is close to zero or, when using an oscilloscope, until the glow line returns to the reference position. This step is essential to compensate for the hysteresis effect that can prevent the probe from reaching the correct zero point. To eliminate hysteresis, the jaws of the current probe should be opened and closed several times before adjusting the zero.
The probe's output is interpreted differently depending on the selected range:
When measuring AC current with an oscilloscope, the oscilloscope's measurement functions can be used to determine the peak-to-peak and effective values. The magnitude of alternating current is typically expressed by its effective value. It is recommended to set the oscilloscope's acquisition mode to "average" for AC current measurements.