4 HARGASSNER Heating technology for Biomass A 4952 Weng OÖ Tel.: +43/7723/5274-0 Fax: +43/7723/5274-5 office@hargassner.at
I Technical Data
Chapter I: Technical Data
1 Dimensions
2 Intended purpose
This automatic wood pellet boiler is designed to heat water only. Only fuels
permitted by Hargassner may be burned in this boiler. Only use the boiler if it is
in technically perfect condition. Rectify errors immediately.
The appropriate operation also covers observation of all items of this operation
manual and the carrying out of inspection- and maintenance works.
3 Fuel quality
Only use fuels that comply with EN ISO 17225-2 (replaces ÖNORM EN 14961-2).
3.1 Wood Pellets (A1)
Ensure these quality standards are adhered to when wood pellets are ordered and
delivered.
• Least possible dust content
• Wood pellets with a hard and shiny surface
• 100% natural wood, no additives, etc.
• Wood pellet class A1 defined in EN ISO 17225-2:2014 and
ÖNORM M 7136
Designation Description Value Unit
B Total width 1165 mm
T Total depth 775 mm
H Total height 1470 mm
Total weight 300 kg
W A R N I N G
Only use released and permitted fuels
Always consult Hargassner before using new fuels.
Have their compatibility with the boiler checked by Hargassner.
Calorific
value
Density Diameter Length
Fine material
rate
>
4.6 kWh/kg 600 - 750 kg/m³ 6 ±1 mm 3.15 - 40 mm < 1%