Loading...
Power on Delay tim
e
3 sec.
functional
AC Power Applied
Transients/Pop
s
ATO Transient 5 mV-peak
10
@ Speaker Outputs
Turn-on Transient 500 mV-peak
700
@ Speaker Outputs
A
C Line cycled from OFF to O
N
Turn-off Transient 500 mV-peak
700
@ Speaker Outputs
A
C Line cycled from ON to OF
F
Efficienc
y
Stand-by Input Power 8 Watts
12
@ nom. line voltage
Maximum allowable input power
under nominal input voltage and
frequency, in stand-by mode (HOT
Power Consumption @ rated power 240 Watts
250
@ nom. line voltage
200 Watts @ 3.5 ohms and
nominal line voltage
Protectio
n
Short Circuit Protection YES
functional
Direct short at output
A
mplifier should resume operation
after short circuit condition is
Thermal Protection YES
functional
A
ny user accessible metal parts
should always remain at 65 degree
C or less for domestic version or 5
5
degree C or less for EU version.
DC Offset Protection YES
functiona
l
DC present at Speaker Out leads
Relay or crowbar (for driver/fir
e
Primary Fuse Rating
USA-Domestic 3.15 Amps
n/a
Type-T or Slo Blo (no DENTORI m
a
User-replacable fuse with
UL/SEMCO rated holder.
SUB-TS14
harman/kardon
3