16
Specifications
Expander/Gate
Threshold Range: Off to +15 dBu
Ratio: 1:1 to 8:1
Attack Time: <100 μsec from maximum depth
Release Time: Program-dependent
Function Switches
SC Enable Routes the external sidechain input signal to the detector.
SC Mon: Routes the sidechain signal to the main output, interrupting the normal audio.
OverEasy®: Activates the OverEasy® compression function.
Contour: Activates the frequency-dependent detector function.
Auto: Activates automatic program-dependent attack and release times, disabling the manual attack and release controls.
I/O Meter: Switches between monitoring input and output levels on the Input/Output Level meter.
Bypass: Activates the direct input-to-output hard-wire relay bypass. Relay automatically hard-wire bypasses unit at power-down and provides a
power-on delay of 1.5 seconds.
Operating Level (rear panel): Switches the nominal operating level between -10 dBV and +4 dBu simultaneously for both input and output levels.
Stereo Couple: Couples both channels for stereo operation. Channel One becomes the master.
Indicators
Gain Reduction 12 LED bar graph at 1,2,4,6,9,12,15,18,21,24,27,and 30 dB.
Input/Ouptut Level 8-segment LED bar graph at -24, -18, -12, -6, 0, +6, +12, and +18 dBu
Compressor Threshold: 3 LED bar graph at Below (-), OverEasy® (O), and Above (+)
Exp./Gate Threshold: 2 LED bar graph at Below (-) and Above (+)
Limiter Threshold: 1 LED to indicate PeakStopPlus™ limiting
Function Switches: LED indicator for each front-panel switch
Power Supply
Operating Voltage: Factory selected: 100-120 VAC 50/60 Hz or 200-240 VAC 50/60 Hz
Power Consumption: 25 Watts
Fuse: 100-120 VAC: T 250 mA L 250V
200-240 VAC: T 125 mA L 250V
Mains Connection: IEC receptacle
Physical
Dimensions: 1.75” H x 19” W x 9” D
44.5 x 483 x 229 mm
Weight: 5.1 lbs.
2.3 kg
Shipping Weight: 7.5 lbs.
3.4 kg
Options
Output Transformer
Per Channel: Jensen® JT-123-dbx or BCI™ RE-123-dbx
Note: Specifications subject to change.