Venting Installation
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
INSTALL VENT WALL PASS-THROUGHS AT CLEARANCES
SPECIFIED BY THE VENT MANUFACTURER.
INSTALLATION IS TO BE PERFORMED BY A QUALIFIED
INSTALLER.
NOTE: Use only 3” diameter type “L” or “PL” venting
system. Be sure to inspect and clean exhaust venting
system frequently.
INSTALLATION IS TO BE PERFORMED BY A
QUALIFIED INSTALLER.
NOTE: All installation clearances and restrictions
must be adhered to.
To reduce probability of reverse drafting during a
power failure, Hearth & Home Technologies strongly
recommends:
• Installingthepelletventwithaminimumverticalriseof
vefeet.Preferablyterminatingabovetheroofline.
• Installinganoutsideairconnectiontotheappliance.
To prevent soot damage to exterior walls, and to prevent
re-entry of soot or ash into the home:
• Maintainspeciedclearancestowindows,doorsandair
inlets,includingairconditioners.
• Ventsshouldnotbeplacedbelowventilatedsofts.
• Avoidventingintoalcovelocations.
• Ventsshouldnotterminateunderoverhangs,decksor
onto covered porches.
• Maintain minimum clearance of 12” from the vent
terminationtotheexteriorwall.
Hearth & Home Technologies assumes no responsibility
for, nor does the warranty extend to, smoke damage
caused by reverse drafting of pellet appliances under
power failure conditions.
NOTE: Read and follow all of the vent pipe manufacturers
instructions on the proper installation and support of
the vent pipe. Adhere to all clearances to combustibles.
DANGER: RISK OF FIRE OR EXPLOSION - DO NOT
BURN GARBAGE, GASOLINE, DRAIN OIL OR OTHER
FLAMMABLE LIQUIDS IN THIS APPLIANCE.
WARNING: RISK OF FIRE
- DO NOT OPERATE WITH FUEL LOADING OR ASH
REMOVAL DOORS OPEN.
- DO NOT STORE FUEL OR OTHER COMBUSTIBLE
MATERIAL WITHIN MARKED INSTALLATION
CLEARANCES.
- INSPECT AND CLEAN ENTIRE VENTING
SYSTEM INCLUDING ALL FLUES AND CHIMNEY
REGULARLY.
WARNING
KEEP COMBUSTIBLE MATERIALS SUCH AS GRASS,
LEAVES, ETC. AT LEAST 3 FEET AWAY FROM THE
POINT DIRECTLY UNDER THE VENT TERMINATION.
(BETWEEN THE VENT AND THE GROUND)
CAUTION
KEEP COMBUSTIBLES AWAY
FROM FLUE OUTLET.