G. Fire Safety
To provide reasonable re safety,the following should be
givenseriousconsideration:
• Installatleastonesmokedetectoroneachoorofyour
home.
• Locatesmokedetectorawayfromtheheatingappliance
andclosetothesleepingareas.
• Followthesmokedetectormanufacturer’splacementand
installationinstructionsandmaintainregularly.
• ConvenientlylocateaClassAreextinguishertocontend
withsmallres.
• Intheeventofahopperre:
• Evacuatethehouseimmediately.
• Notifyredepartment.
• Installationanduseofanydamagedappliance.
• Modicationoftheappliance.
• InstallationotherthanasinstructedbyHearth&Home
Technologies.
• Installation and/or use of any component part not
approvedbyHearth&HomeTechnologies.
Operating appliance without fully assembling all
components.
• DoNOTOverre.
Or any such action that may cause a re hazard.
Fire Risk:
Hearth & HomeTechnologies disclaims
anyresponsibilityfor,andthewarrantywill
bevoidedby,thefollowingactions:
Inspect appliance and components for
damage. Damaged parts may impair safe
operation.
• DoNOTinstalldamagedcomponents.
• DoNOTinstallincompletecomponents.
• DoNOTinstallsubstitutecomponents.
Reportdamagedpartstodealer.
WARNING
!
WARNING
!
DO NOT RELOCATE OR BYPASS ANY OF THE
SAFETY CONTROLS IN THE ORIGINAL FURNACE
INSTALLATION.
WARNING
!
Vent Congurations:
To reduce probability of reverse drafting during shut-
down conditions, Hearth & Home Technologies strongly
recommends:
• Installingthepelletventwithaminimumverticalrunof
vefeet,preferablyterminatingabovetheroofline.
• Installingtheoutsideairintakeatleastfourfeetbelowthe
venttermination.
Topreventsootdamagetoexteriorwallsofthebuildingand
topreventre-entryofsootorashintothebuilding:
• Maintainspeciedclearancestowindows,doors,andair
inlets.
• Ventsshouldnotbeplacedbelowventilatedsofts.Run
theventabovetheroof.
• Avoidventingintoalcovelocations.
• Vents should not terminateunderoverhangs, decks or
ontocoveredporches.
Maintainminimum clearance of 12 inches from the
ventterminationtotheexteriorwall.Ifyouseedeposits
developing on the wall, you may need to extend this
distancetoaccommodateyourinstallationconditions.
Hearth & Home Technologies assumes no responsibility
for, nor does the warranty extend to, smoke damage
caused by reverse drafting of pellet appliances under
shut-down or power failure conditions.