EasyManua.ls Logo

Harman PF-120 - Fan;High Limit Control

Harman PF-120
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/1425
3-90-08121i
G. Fan/High Limit Control
1. TheFanControlmustbeplacedinthedischargeplenum
approximately11inchesabovethedischargeopeningof
thefurnace,asclosetocenteraspossible.
Note: Thebestplaceisonthesamesideastheashdoor
becauseofeaseofaccess.Figure5.16.
2. Installtheexandwiring.
3. Makesurethattheueventingwillnotinterferewiththe
extotheFanControl.
4. PryoutoneofthebottomknockoutsoftheFanControl.
Installthe90°degreeexconnectorasshowninFigure
5.17.Oneofthelocknutsstayontheoutsideofthebox
andonegoesontheinsidetotightentheconnectorinto
place.Thisallowsformaximumroomforthewiresaround
theswitches.
5. REMOVE THE COPPER JUMPER BETWEEN THE
LIMIT AND CONTROL SWITCHES. (It is not needed.)
6. Connect the two VIOLET & Black wires to the FAN
CONTROL switch. (It doesn’t matter which wire is on
whichscrew).Figure5.17.
7. ConnecttheWHITEandSKYBLUEwirestotheLIMIT
switch.(Itdoesn’tmatterwhichwireisonwhichscrew).
Figure5.17.
8. Makesurethatallofthewiresareoutofthewaywhen
closingthecover.(Excesstwistingandpinchingofthe
wirescouldcauseashortcircuit.)
9. HIGH LIMITsetup:Rotatethehighlimitpointerclockwise
untilitisagainstthetamper-proofscrew.(Neveradjust
thisscrew)
10. FAN CONTROLsetup:Movefurthestleftpointertothe
120°position,thenmovethepointertotherightofitto
the150°position.Figure 5.17.Thisis agoodstarting
point,however,thesettingsbetweenthe2pointersmay
needtobechangedifshortcyclingoccurs.
Note:Thisisthebestfancontrolpositionwehave found
during factory testing. These fan control settings can be
adjustedifdesired.
NOTE: KEEP THE FAN/LIMIT CONTROL INSTRUCTIONS
WITH THE OWNERS MANUAL FOR FUTURE REFERENCE.
NOTE: If fans are used in the fuel storage area, they
should be installed so as not to create negative pressure
in the room where the solid-fuel-burning appliance is
located.
Highlimitfancontrol
High Limit
Set point
Control
Fan Control Set points
Limit
Locknutsoutsideandinside
Figure 5.16
Figure 5.17

Other manuals for Harman PF-120