Dry Seasoned Wood Only! Save These InstructionsHarman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15
Chimney Breach Fireplace Conversion with Non-Combustible Wall
The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a
Floor or Ceiling.
Minimum clearance to
unprotected ceiling 15”
Chimney connector
sealed at thimble
Flue liner with required air space
Minimum of three sheet
metal screws per joint of
chimney connector
Mantel and trim protection
Airtight
insulated
clean-out
Damper closed
and sealed with
non-combustible
material
Combustible Floor
Floor Protection*
*Floor protection in accordance with Solid Fuel Appliance Listing