122
Program SINCGARS Configuration (1)
8 VWX
PGM
PGM
VULOS CONFIG
SINCGARS CONFIG
PGM - SINCGARS
CUE CONFIGURATION
HOPSET / LOCKOUT
MASTER / MEMBER
PGM – SINCGARS – MASTER / MEMBER
SINCGARS RADIO TYPE
TO SCROLL / ENT TO CONT
MEMBER
PGM - SINCGARS
MASTER / MEMBER
HOPSET / LOCKOUT
CUE CONFIGURATION
PGM – SINCGARS – CUE CONFIGURATION
CUE FREQUENCY
0.0000 MHz
ENTER 30.0000 TO 87.9750
3
PGM – SINCGARS – CUE CONFIGURATION
CUE SQUELCH TYPE
TO SCROLL / ENT TO CONT
TONE
PGM – SINCGARS – CUE CONFIGURATION
ENABLE CUE NOTIFY
TO SCROLL / ENT TO CONT
YES
•MASTER / MEMBER configuration. The Net Control Station (NCS) or Alternate
NCS should be setup as a MASTER radio. All other radios in the net should be
set as MEMBERs. The radio defaults to Member, to change the radio to Master
do the following:
• Press the PGM button
• Select SINCGARS CONFIG
• Select MASTER/MEMBER
• Change to MASTER
• Next the CUE needs programmed.
• Select CUE CONFIGURATION
• Enter the CUE frequency (30 to 87.975 MHz)
• Set the CUE SQUELCH TYPE to TONE
• For Master set ENABLE CUE NOTIFY to YES, Members set it to NO.