Program SINCGARS Configuration (2)
PGM - SINCGARS
MASTER / MEMBER
CUE CONFIGURATION
HOPSET / LOCKOUT
PGM - SINCGARS HOP / LOCKOUT
VIEW HOPSETS
VIEW LOCKOUTS
COPY HOPSET
PGM SINCGARS HOP / LOCKOUT - COPY
COPY HOPSET FROM
TO SCROLL / ENT TO CONT
01 [ F300 ]
PGM SINCGARS HOP / LOCKOUT - COPY
COPY HOPSET TO
ENTER 01 TO 25
07 [ EMPTY ]
PGM SINCGARS HOP / LOCKOUT - COPY
NEW HOPSET ID
F456
ENTER 000 TO 999
PGM - SINCGARS HOP / LOCKOUT
COPY HOPSET
VIEW LOCKOUTS
VIEW HOPSETS
. . SINCGARS - HOP / LOCKOUT - HOPSETS
01 - F300
02 - F100
03 - F200
. . SINCGARS - HOP / LOCKOUT - HOPSETS
07 - F456
08 - EMPTY
09 - EMPTY
•HOPSET / LOCKOUT menu is used to change Net IDs and view Net IDs. It is
recommended that the operator set the Net IDs prior to programming the System
Presets!
• Select HOPSET / LOCKOUT
• COPY HOPSET is used to change the Net ID in a Hopset Compartment and to
create additional Net IDs in the empty compartments.
• Select COPY HOPSET
At COPY HOPSET FROM, scroll
to select a compartment, press ENT.
Only filled compartments can be selected.
At COPY HOPSET TO, type the compartment number you wish to create
the Net ID in (01 to 25), press ENT. COPY HOPSET TO defaults to the
first empty compartment.
At NEW HOPSET ID, enter the 3 digit Net ID. Repeat to create more Net
IDs.
• Select VIEW HOPSETS and scroll down to view what Net ID is in what
compartment.