125
Program SINCGARS
System Presets (2)
. . – SYS PRESETS – CFG – 05 - SINCGARS
TRAFFIC MODE
TO SCROLL / ENT TO CONT
VOICE
. . – SYS PRESETS – CFG – 05 - SINCGARS
HOPSET COMPARTMENT
TO SCROLL / ENT TO CONT
07 [ F456 ]
. . – SYS PRESETS – CFG – 05 - SINCGARS
SC FREQUENCY
0.000 MHz
ENTER 30.0000 TO 87.9750
3
. . – SYS PRESETS – CFG – 05 - SINCGARS
SC SQUELCH TYPE
TO SCROLL / ENT TO CONT
TONE
. . – SYS PRESETS – CFG – 05 - SINCGARS
TX POWER LEVEL
TO SCROLL / ENT TO CONT
HIGH
. . – SYS PRESETS – CFG – 05 - SINCGARS
BAUD RATE
TO SCROLL / ENT TO CONT
16000
. . – SYS PRESETS – CFG – 05 - SINCGARS
DTE DATA MODE
SYNCHRONOUS
PRESS ENT TO CONTTINUE
•Select the TX POWER LEVEL. The TX Power Level choices are the same as
LOS; HIGH, MEDIUM, LOW, & USER.
• Select VOICE for TRAFFIC MODE. Two other choices are DATA and
DATA/VOICE. If either is selected then the BAUD RATE must be selected.
Choices are RS232, 600, 1200, 1200N, 2400, 2400N, 4800, 4800N, 9600N, &
16000. DTE DATA MODE is set to SYNCHRONOUS and cannot be changed.
• Select the HOPSET COMPARTMENT. The Net ID is displayed next to the
Compartment number.
• If SINGLE CHANNEL was selected for OPMODE, then enter a SC
FREQUENCY. Note: The OPMODE can be changed from the main operational
screen. Therefore, each SINCGARS System Preset can be programmed with a
Net ID and a SC Frequency.
• Select TONE for the SC SQUELCH TYPE. NOISE and OFF are also available.