134
SINCGARS CUE and
Cold Start ERF (3)
R BAT SNCGR DIG VINSON CT
05 – SNGRS02 FH
VOC ---- 456 TEK01
---CUE INCOMING ---
R BAT SNCGR DIG VINSON CT
ENTER FREQUENCY
0.000 MHz
ENTER FREQUENCY
3
R BAT SNCGR DIG VINSON CT
CUE
NORMAL ERF
COLD START ERF
R BAT SNCGR DIG VINSON CT
COLD START ERF
TO SCROLL / ENT TO CONT
TRANSMIT
R BAT SNCGR DIG VINSON CT
SELECT SET
TO SCROLL / ENT TO CONT
07 [ F456 ]
R BAT SNCGR DIG VINSON CT
COLD START ERF
TRANSMITTING
KEYED
R BAT SNCGR DIG VINSON CT
COLD START ERF
TRANSMIT COMPLETE
PRESS CLR / ENT TO EXIT
CLR
X 3
Master station responding to a CUE and Cold Start ERF request.
• When a station CUEs the Master station, CUE INCOMING will flash at the
bottom of the screen and a tone will be heard from the speaker. Press the CALL
button.
• Select CUE; the screen changes to the CUE channel.
• Reply to the CUEing station in CT.
• Press CLR once then select COLD START ERF.
• Select TRANSMIT. RECEIVE is the other choice.
• Select the HOPSET Compartment to be transmitted.
• The screen will show the ERF being transmitted then complete.
• Press the CLR button 3 times to return to the Main Operational screen and
perform a radio check.