135
SINCGARS Normal ERF (1)
R BAT SNCGR DIG VINSON CT
CUE
COLD START ERF
NORMAL ERF
R BAT SNCGR DIG VINSON CT
NORMAL ERF
TO SCROLL / ENT TO CONT
TRANSMIT
R BAT SNCGR DIG VINSON CT
SELECT SET
TO SCROLL / ENT TO CONT
07 [ F456 ]
R BAT SNCGR DIG VINSON CT
NORMAL ERF
TRANSMITTING
KEYED
R BAT SNCGR DIG VINSON CT
NORMAL ERF
TRANSMIT COMPLETE
PRESS CLR / ENT TO EXIT
CLR
X 3
The Normal ERF procedure is used to update Frequency Hopping data during
normal operation. The Master station loads the new FH data but does not delete
the old data from the radio. The Master station must inform the Member stations
when the new FH data will take effect. A normal ERF is not sent over the Manual
Frequency but over an active FH Net. The Normal ERF procedure is very similar
to the Cold Start ERF.
Master station:
• Press CALL button
• Select NORMAL ERF
• Select TRANSMIT
• Select the HOPSET Compartment to be transmitted.
• The screen will show the ERF being transmitted then complete.
• Press the CLR button 3 times to return to the Main Operational screen