65
Loading Single COMSEC Key (3)
SKL settings
If using a AN/PYQ-10 SKL use the following steps:
• After you have logged into the SKL select the Keys Ta b.
• Select the correct key then press the LOAD icon in the top right of the screen.
There may be more than one Edition under a short title, expand the tree and
select the correct Edition.
• Select DS-102 for the Protocol and KYK-13 for the Activation Mode. Press
OK.
• Press OK at the Ready to Send Key screen.
• When the Status screen displays Press INITIATE Button…, press the ENT
button on the radio.