EasyManua.ls Logo

Harris Gates One 994 9202 002 - VSWR Detector

Default Icon
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power Output 1000W 800W 600W 400W 200W 100W
PA Volts 92.5 84 74 62 46.5 35
PA Amps 12.5 11.3 10 8.4 6.4 4.9
PDM Level 6.4 5.8 5.1 4.3 3.2 2.4
Supply Voltage 242 244 246 248 252 254
Supply Current 4.8 4.1 3.3 2.5 1.6 1.1
RF Drive 7.4 7.4 7.4 7.4 7.4 7.4
VSWR Detector Null 0 0 0 0 0 0
VSWR Detector Null Set 5.3 5.3 5.3 5.3 5.3 5.3
Underdrive Set 6.4 5.8 5.1 4.3 3.2 2.4
Supply Current Set 8.3 8.3 8.3 8.3 8.3 8.3
Supply Voltage Set 297 297 297 297 297 297
Battery 9.8 9.8 9.8 9.8 9.8 9.8
The readings above are typical readings. Refer to the Factory Test Data Sheets supplied for readings actually obtained during factory
tests.
Table 2-7. GATES ONE
Typical Readings at 1340kHz
Power Output 2500W 2000W 1500W 1000W 500W 200W
PA Volts 98.5 90.0 79.0 66.0 50.0 35.0
PA Amps 28.7 26.1 23.0 19.0 14.0 10.0
PDM Level 6.8 6.2 5.5 4.6 3.4 2.4
Supply Voltage 249 250 252 257 260 265
Supply Current 12.0 10.0 8.0 5.0 3.0 2.0
RF Drive 8.9 8.8 8.8 9.0 9.0 9.0
VSWR Detector Null 0 0 0 0 0 0
VSWR Detector Null Set 6.6 6.6 6.6 6.6 6.6 6.6
Underdrive Set 6.7 6.2 5.5 4.5 3.4 2.4
Supply Current Set 23.5 23.5 23.5 23.5 23.5 23.5
Supply Voltage Set 299 299 299 299 299 299
Battery 9.8 9.8 9.8 9.8 9.8 9.8
The readings above are typical readings. Refer to the Factory Test Data Sheets supplied for readings actually obtained during factory
tests.
Table 2-8. GATES TWO
Typical Readings at 800kHz
2-10 888-2314-001 Rev. AC: 2/29/00
WARNING: Disconnect primary power prior to servicing.

Table of Contents