A-2 888-2595-001 12/20/11
WARNING: Disconnect primary power prior to servicing.
ZX Series
Appendix A - FM Web Remote Option
In addition to webpage-based control, the web remote also responds to SNMP v1 GET
and SET commands. It can be set to send a generic trap and/or e-mail notification when
a user-adjusted low power alarm threshold is passed.
The physical implementation of the web remote is a 76mm x 102mm PC board that
plugs into the transmitter I/O board via a pair of 34-pin headers. It receives its power
from the I/O board and consumes approximately 150mA at 4V to 5V DC. See Figure
A-1 for a photo of the web remote installed on the I/O board.
The web remote provides monitoring and control not only for the amplifier chassis but
also the Harris Flexstar Main/Alt Controller (981-0193-001) and ZX System Metering
Panel (981-0090-070) via the normal D-sub connections to these units, when present.
Figure A-1 Physical appearance of FM Web Remote board.
[1] I/O panel removed from rear face of amplifier chassis. (reverse face shown,
normally inside chassis).
[2] I/O PC board (901-0203-551).
[3] FM Web Remote PC board (901-0203-391T).
[4] 3V lithium coin-cell battery for on-board clock (660-0068-000).
[5] 50C ribbon cable connection to rest of amplifier chassis.
[5]
[3]
[2]
[1]
[4]