Camera body 503CW
Adjustment
October 1996
Revision 0
5:4
Adjustment of the release mechanism
Check that the release bar (30375) is free from the
signal arm pawl. Adjust by carefully bending the
forward part of the signal arm. Use tool V-2200.
Minimum free play: 0.2 mm.
With the camera fully cocked the release bar should
protrude a maximum of 0.9 mm through the rear plate.
Adjust this by bending the release arm (13357) using
tool V-2224.
Fig. 35.
The mirror function should be checked and possibly
adjusted before proceeding to adjust the release
mechanism.
The mirror should be locked by the mirror catch lever
(13356-1). Movement can be increased or reduced by
adjusting the mirror actuating lever (13362).
Adjustment is carried out by holding the arm fixed
using tool V-2205 and gently bend the forward part of
the arm using tool V-2201. Bend downwards for
increased mirror movement.
Note! The inner side cover (22813) must be removed
before an adjustment can be made.
The mirrors overtravel should be min. 1 mm. Lubricate
the mirror cam (22355) with grease.
Fig. 36.
Fig. 36
min. 1 mm
1336222335
13357
max. 0.9mm
Fig. 35
min. 0.2 mm 30375
13356-1

Other manuals for Hasselblad 503CW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hasselblad 503CW and is the answer not in the manual?

Hasselblad 503CW Specifications

General IconGeneral
Camera TypeMedium format SLR
Exposure ModesManual
FocusManual focus
Lens MountHasselblad V mount
Shutter TypeFocal-plane shutter
Flash Sync1/90 sec
MeteringExternal metering required
ViewfinderInterchangeable viewfinders (waist-level, prism)
Shutter Speed1 sec to 1/500 sec, Bulb
Flash Sync Speed1/90 sec

Related product manuals