EasyManua.ls Logo

HATO HT 600 - Adjusting the Closing Force; Activation of the Photocells Function; Auto-Closing Function

HATO HT 600
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
function. We turn on the ventilation function and only now log the
buttons of all remote controls for opening / closing.
ADJUSTING THE CLOSING FORCE
When setting the closing force, pay attention to whether the drive closes
the gate freely, and at the same time check whether the chamber seal
has retained its geometry. In the event of encountering an obstacle
(exceeding the set force), the gate will stop and open fully immediately.
The procedure for setting the closing force:
1.
Press and hold “P”, until “P1” displays.
2.
Press once, until P2displays.
3.
When pressing “P” again, you will see current closing force settings.
Press “to increse, orto reduce the operating force of the drive.
Maximum froce: F9, minimum F1.
4.
Press “P” to confirm settings. Default value is “F5”.
ACTIVATION OF THE PHOTOCELLS FUNCTION
Photocells are used to protect the gate during closing against hitting an
obstacle in the gate's light. In a situation where the beam of photocells
is cut, the gate will start opening immediately or, when it is fully open,
it will remain motionless.
Procedure for activating the photocells service:
1.
Press and hold “P”, until “P1” displays.
2.
Press (twice), until P3displays.
3.
By pressing “P” again, you will see current settings.
By pressing ““H1” will display (photocell support is on)
By pressing ““H0” will display (photocell support is off)
Press “P” to confrim settings.
4.
If you are not using photocells, make sure that their operation is turned
off.
AUTO-CLOSING FUNCTION
Auto-closing determines the time after which the gate, after complete
opening, starts closing. The auto-closing function, for safety reasons,
can only be activated when photocells are installed and the photocells
support function is enabled. Activating the auto-closing function
without photocells may result in an accident. If the gate is partially
open then the auto-closing function does not work.
Procedure for activating the photocells service:

Related product manuals