17
VENTILATION FUNCTION
If there is a need for garage ventilation, then this function can be
turned on. It consists in the fact that with the remote control button
(other than the button for opening / closing the gate) the gate is
opened to the programmed height n x 8cm (n=1÷6) .
Before activating the ventilation function, the buttons of all remote
controls must be logged in to the drive to operate this function
Activation of the ventilation function:
1.
Press and hold “P”, until “P1” displays.
2.
Press “until P7displays.
3.
Then press or to adjust settings.
The displayed “r0” means that the ventilation function is disabled,
The displayed “r1” to “r6. Ventilation level [(1 to 6) x 8cm].
4.
Press “P” to confirm.
5.
After switching on the ventilation function for the first time, we need to
log in the buttons of all remote controls for opening / closing.
Subsequent activation and deactivation of this function does not require
logging in the remotes anew.
PEDESTRIAN MODE
1.
The pedestrian mode works only when the drive has the photocell support
switched on. In a situation where the garage door is open, after cutting the
photocells, the gate will start closing after a set time.
2.
Press and hold “P”, until “P1” displays.
3.
Press ”, until “P8” displays.
4.
Then press or to adjust settings.
“00” displayed – the function is blocked
“01” to ”10” displayed – set time between 1 and 10 seconds.
5.
Press “P” to confirm.
Default setting is “00”.
MAINTENANCE, USE
Attention! A poorly adjusted garage door can affect the service life of the drive due to incorrect loads and void the
warranty.
1
Check if the garage door works smoothly. (unlock the release and manually raise and lower the gate)