Press and hold “P”, until “P1” displays.
Press “▲”(three times), until “P4” displays.
By pressing “P” again, you will see current settings.
By pressing “▲” you add 1 minute, by pressing “▼” you subtract
1 minute. Maximum time is “b9”, minimum “b0”.
Press “P” to confirm settings.
Default setting is “b0”- Auto-closing function disabled.
The gate lock function is used to prevent the gate from opening
unintentionally. (if the remote control in your pocket is accidentally
pressed, it may start the gate), after activating this function, to open
the gate, first press the button “D” and then the button logged in to
open the gate. If the interlock function is used, button "D" must not be
logged to open the gate.
The interlock function only works when the gate is completely closed. If
the gate is in a different position, to control it, use only the button
logged in to control it.
Procedure for activating the photocells service:
Press and hold “P”, until “P1” displays.
Press “▲”, until “P5” displays.
By pressing “P” again, lock settings will appear.
By pressing “▲” “Lc” will display – the lock is on.
By pressing “▼” “uL” will display – the lock is disabled.
Press “P” to confirm settings.
The interlock function works only when the gate is fully closed.
ADJUSTING THE OPENING FORCE
If there is a risk of the gate becoming jammed while it is being lifted (eg
due to the presence of objects), then the opening force must be set so
that it can rise freely and evenly. If there is an obstacle, the door stops
immediately.
Procedure for activating the photocells service
Press and hold “P”, until “P1” displays.
Press “▲”, until “P6” displays.
By pressing “P”, you will see the current opening force settings.
Press “▲” to increase or “▼” to reduce the operating force of the
drive. Maximum force F9, minimum F1.
Press “P” to confirm settings. Default valute is “F9”.